| Sign In | Join Free | My carsrow.com | 
 | 
| Categories | Laboratory Test Equipment | 
|---|---|
| Brand Name: | AI | 
| Model Number: | 4530F | 
| Certification: | ISO | 
| Place of Origin: | China | 
| MOQ: | 1 set Atomic Absorption Spectroscopy | 
| Price: | Negotiable | 
| Payment Terms: | L/C, T/T, Western Union | 
| Supply Ability: | 20 sets per month | 
| Delivery Time: | Atomic Absorption Spectroscopy packed in 20 days | 
| Packaging Details: | Plywood case | 
| Test method: | Atomic Absorption Spectrometry AAS | 
| Wavelength Range: | 190 ~ 900nm | 
| Wavelength Accuracy: | ±0.15nm | 
| Lamp Turrets: | 8 PCS | 
| Spectrum Bandwidth: | 0.1nm, 0.2nm, 0.4nm, 1.0nm And 2.0nm | 
| The highest temperature: | 3000℃ | 
| The largest temperature rising speed: | ≥2000℃/S | 
| Dimension of main unit: | 550mm×450mm×300mm | 
| Company Info. | 
| Advanced Instruments Co.,Limited | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
Features:
This AAS machine is complete automatic controlling system;
The AA spectrophotometer can be worked with advanced graphite
furnace temperature controlling technology;
Safe, reliable and convenient flame system;
Multi-functional software workstation;
This flame system atomic absorption spectrophotometer is ompletely
controlled by PC, can flexibly select the flame and graphite
furnace atomizer (optional);
Integrated floated optical platform design can obviously improve
the optical system shock resistance and can keep stable though use
the optical signal for a long term;
Eight light stands can be changed automatically and preheat the
eight element lights meantime as well as optimize the working
condition of the hollow cathode lamp;
Position adjusting: the best height of the flame burner and can
automatically set the front and rear positions;
Fully automated wavelength scanning and peak searching;
Complete safety chains protection equipment: the function of
warning and automatic safety protection towards the wrong burner,
leakage of the gas, under voltage of air and the abnormal flameout;
Deuterium lamp and self-absorption background regulation;
Data processing: super strong database, possesses more than 500
data self-storage and cut-off storage function, can store the
analyzed result with the form of EXCEL and the testing method and
the result can be randomly called;
Measuring method of AAS machine: flame absorption method and
emission method;
Result printing: parameter printing, data result printing and
diagram printing;
Instrument Configuration:
Atomic Absorption Spectrophotometer 1pc
Air compressor without noise 1pc
PC workstation: computer, HP inkjet, apparatus operating software
(the object can be prevailed on the specific configuration)
A set of accessories (including Acetylene reducing valve, one
copper and manganese element lamp and air filter)
Specifications:
| Wavelength range | 190 ~ 900nm | 
| Spectral bandwidth | Can automatically change between 0.1nm, 0.2nm, 0.4nm, 1.0nm and 2.0nm | 
| Accuracy of the wavelength | ±0.15nm | 
| Receptivity of the wavelength | ≤0.04nm | 
| Base line stability | ≤0.002A/30min (Cu) | 
| Characteristic viscosity | 0.02μg/ml/1% (Cu) | 
| Checking limit | 0.004μg/ml (Cu) | 
| Preciseness | 0.5% | 
| Grating | 1800 lines/mm | 
| Inflamer | All-metal titanium burner | 
| Atomizer | Effective glass atomizer | 
| Lamp stand | Eight lamps | 
| D2 background correction ability | When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method | 
| Size and weight | 700mm×550mm×450mm 75Kg | 
| Power source | 220V±22V AC | 
Flame System:
| Acetylene air burner | 100mm | 
| Nitrous oxide acetylene flame head | 50mm | 
| Ignition dynamic baseline drift | ≤0.006A/30min | 
| (Cu) Characteristic viscosity | ≤0.025μg/ml/1% | 
| Related standard deviation of the accuracy | ≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml) | 
| Safety system | Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner | 
Graphite Furnace:
| The highest temperature | 3000℃ | 
| The largest temperature rising speed | ≥2000℃/S | 
| Characteristic quantity | Cd≤0.5×10-12g Cu≤0.5×10-11g | 
| Accuracy | Cu≤3% Cd≤3% | 
| Size and weight | 550mm×450mm×300mm 65Kg | 
| Safety system | Over current protection | 
| Protection | Low air pressure alarm, low cooling water flow alarm | 
| Power source and power | 220V±22V AC 7000W | 
Spares package of 4530F Automatic Atomic Absorption Spectroscopy AAS Machine


|   | 
 K and Na Digital Flame Photometer With LCD Touch Screen LPG Burning Gas
                                                                                    
                        
                        
                        
                                                            K and Na Digital Flame Photometer With LCD Touch Screen LPG Burning Gas
                                                    
                        
                     Oxygen Bomb Calorimeter For Measuring Calorific Values Of Liquid And Solid Samples
                                                                                    
                        
                        
                        
                                                            Oxygen Bomb Calorimeter For Measuring Calorific Values Of Liquid And Solid Samples
                                                    
                        
                     UOP603 Gas Chromatagraph Testing Equipment Trace CO CO2 In Hydrogen Light Gaseous
                                                                                    
                        
                        
                        
                                                            UOP603 Gas Chromatagraph Testing Equipment Trace CO CO2 In Hydrogen Light Gaseous
                                                    
                        
                     Flame and Furnace AA Atomic Absorption Spectrophotometer with PC and Printer
                                                                                        
                                                        
                        
                        
                        
                                                            Flame and Furnace AA Atomic Absorption Spectrophotometer with PC and Printer
                                                    
                        
                     G Series Visible Spectrophotometer Visible Spectrophotometry Instrument
                                                                                    
                        
                        
                        
                                                            G Series Visible Spectrophotometer Visible Spectrophotometry Instrument
                                                    
                        
                     (0.00~14.00)pH Automatic Potential Titrator with RS-232 Communication Port
                                                                                    
                        
                        
                        
                                                            (0.00~14.00)pH Automatic Potential Titrator with RS-232 Communication Port
                                                    
                        
                     Multi-parameters Water Quality Meter for pH, pX, ORP,Ion concentration,TDS
                                                                                    
                        
                        
                        
                                                            Multi-parameters Water Quality Meter for pH, pX, ORP,Ion concentration,TDS
                                                    
                        
                     Digital Laboratory Test Equipment Isoperibol Oxygen Bomb Calorimeter
                                                                                    
                        
                        
                        
                                                            Digital Laboratory Test Equipment Isoperibol Oxygen Bomb Calorimeter
                                                    
                        
                     Laboratory Refrigerated Centrifuges To Separate Components Of Blood For Analysis
                                                                                    
                        
                        
                        
                                                            Laboratory Refrigerated Centrifuges To Separate Components Of Blood For Analysis
                                                    
                        
                     Touch Screen Volumetric Karl Fischer Tester With Measuring Range 0.1mg~250mg
                                                                                    
                        
                        
                        
                                                            Touch Screen Volumetric Karl Fischer Tester With Measuring Range 0.1mg~250mg