Customizable 10kV Transformer Reactor Test System Integrated Split Type
|
... 50150/IEC 60076-3. It adopts a steel structure control console with compact structure and high cost performance. It can perform no-load test, load test, power-frequency voltage withstand test, induced voltage withstand test, etc....
Wuhan Ourui Electric Co., Ltd
|
Automatic Tuning Variable Frequency Resonant Test Set For Transformers Generators Test
|
...Test Set For Transformers, Generators and Cables Test General Information: SXBP Variable Frequency Resonant Test Set are widely used in Electric Power, Oil, Chemical Industry, etc., applicable to connecting and preventing tests for capacitive equipment with high-capacity, high-voltage. It is composed by control cabinet, excitation transformer, high voltage reactor......
Sansion Power Electric Co., Ltd.
|
Transformer Comprehensive Test Bench with Test Transformer and Voltage Regulator Complete Set
|
... capacity 50kVA to 5000kVA, in voltage 6, 11, 24, 36kV/380V, and impedance ≤4~8%. The Tested items included transformer no-load/load test, temperature rise test, power frequency withstand voltage test, and induced withstand voltage test , etc, It’s...
Wuhan Mingyang Technology Co., Ltd
|
Auto Transformer Comprehensive Test Bench With Ratio / Resistance High Voltage / Partial Discharge Test Functions
|
...Transformer Comprehensive Test Bench for Power Transformer Factory Testing with Ratio, Resistance, Loss, High Voltage and Partial Discharge Test Functions Product Description The Automatic Transformer Comprehensive Test Bench is a complete integrated testing solution designed for power transformer manufacturers, transformer maintenance companies, electrical laboratories and power utilities. The system combines multiple transformer...
Sansion Power Electric Co., Ltd.
|
RSRR Transformer Testing Equipment Integrated DC Resistance and Variable Ratio Testing System
|
...Transformer Testing Equipment Integrated DC Resistance and Variable Ratio Testing System Product Description In the production process of semi-finished products and finished products of power transformers, according to the preventive test regulations of the ministry of power of the People's Republic of China, the transformer in operation is required to be tested regularly in turn ratio or voltage ratio before the newly installed transformer...
Wuhan Rising Electric Co., Ltd.
|
ZX-YJS Tan Delta Test Set Transformer Oil Testing Equipment Insulating Oil Dielectric Loss Tester
|
ZX-YJS Insulation Oil Tan Delta Tester Product introduction ZX-YJS Insulation Oil Tan Delta Tester is a high-precision integrated testing instrument designed and manufactured according to GB/T5654-2007 measurement of relative permittivity, dielectric loss ......
Wuhan GDZX Power Equipment Co., Ltd
|
Durable Transformer Oil Testing Equipment Insulation Oil Volume Resistivity Test
|
Automatic Insulation Oil Dielectric Loss Tester , Insulation Oil Volume Resistivity Tester I. Products Description Model FKYJS Automatic Insulation Oil Dielectric Loss Tester is a high-precision instruments used for insulating oil liquid medium dielectric ......
WUHAN FANKE HAIWO HIGH VOLTAGE TECHNOLOGY CO.,LTD.
|
Customized Cable Fault Test Van Power Transformer Comprehensive Test Vehicle
|
XHGG555 Vehicle mounted cable diagnosis and fault location system The following XHGG555 introduces the vehicle cable diagnosis and fault detection system. The transformer, circuit breaker and other detection systems can also be customized according to ......
Xi'an Xu&Hui Electromechanical Technology Co., Ltd.
|
Transformer Oil Test Set Dielectric Dissipation Factor Volume Resistivity Meter
|
Insulation Oil Dielectric Dissipation Factor Volume Resistivity Tester I. Introduction: Automatic Dielectric Dissipation Factor Tester is a high-precision instrument, which can be applied to measure dielectric loss angle and Volume Resistivity of ......
Advanced Instruments Co.,Limited
|
0.005 Class CT PT Test Equipment Integrated With Source
|
Standard Current Transformer HLB-32G series Technical Parameter Primary Wound primary winding 5….100A or 5….480A, 50/60HZ (more option available) Applied primary Applied primary: 100….3200A (1…10, maximum 12 turns) or 480A-3200A (1-2 turns) (more option ......
Metrum Henan Electric Technology Co.,Ltd.
|
