| Sign In | Join Free | My carsrow.com |
|
| Categories | Electromagnetic Flow Meter |
|---|---|
| Brand Name: | Endress+Hauser |
| Certification: | CE |
| Place of Origin: | Switzerland |
| MOQ: | 1PCS |
| Payment Terms: | L/C,D/A,D/P,T/T,Western Union,MoneyGram |
| Supply Ability: | 1000 Piece/Pieces per Week negotiable |
| Delivery Time: | 5-8 work days |
| Packaging Details: | each unit has individual box and all boxes are packed in standard packages or customers requests available |
| Model Number: | Proline Promass U 500 |
| Wetted materials: | Measuring tubes: Stainless steel 1.4435, 316L |
| Measured variables: | Mass, density, temperature |
| Max. measurement error: | Mass flow (liquid): ±0.5% |
| Measuring range: | 0 to 75 kg/h (0 to 165,3 lb/min) |
| Max. process pressure: | 6 bar (87 psi) |
| Company Info. |
| Xi'an Kacise Optronics Co.,Ltd. |
| Verified Supplier |
| View Contact Details |
| Product List |
"Specs at a glance
Max. measurement error
Mass flow (liquid): ±0.5%
Measuring range
0 to 75 kg/h (0 to 165,3 lb/min)
Medium temperature range
3 to 60°C (37.4 to 140°F)
Max. process pressure
6 bar (87 psi)
Wetted materials
Measuring tubes: Stainless steel 1.4435, 316L
Hose connection nipple: Makrolon Rx 1805 polycarbonate" "Field of
application
Promass U 500 is the ideal single-use flowmeter for
biopharmaceutical applications in the life sciences industry. It
represents the response to the shift from multi-use to single-use
devices and from batch to continuous manufacturing. Offering
multivariable measurement, Promass U 500 provides enhanced
reliability, high accuracy, and industry compliance according to
cGMP. The flowmeter is especially suited for up- and downstream
applications in the monoclonal antibodies (mAb) process.
The sensor comprises a disposable part, available in four line
sizes, and a permanently installed base unit, fitting all line
sizes. Heartbeat Technology automatically recognizes the flow range
and verifies the validity of the factory calibration after
installation. This simplifies commissioning and eliminates the need
for calibration in the field. Equipped with built-in web server,
WLAN, and up to 4 I/Os, the transmitter provides easy operation and
additional process and device information." "Benefits
Best-in-class measuring accuracy – Coriolis technology with
multivariable measurement
Highest turndown ratio – one sensor fits all line sizes of disposable
cGMP compliance – designed according to the latest standards and guidelines, equipped with required attributes and documentation
Simple, fast commissioning – one-hand mounting and automated calibration data transfer
Self drainability or air bubble escape – thanks to different mounting angles
No field calibration needed – automated verification with integrated Heartbeat Technology
Digital integration – modern single pair Ethernet based
communication protocols" "Measuring principle
Coriolis
Product headline
Single-use specialist for Biotech applications, with a remote
version with up to 4 I/Os.
Modern fieldbus communication protocols (2-wire).
Highest measurement performance for liquids in single-use processes
for the Life Sciences Industry.
Sensor features
One sensor fits all DN – single variant with 4 disposable line
sizes provides highest turndown ratio . One-hand mounting of
disposable – easy
commissioning due to intuitive clamping mechanism. Mounting angle -
self drainabillity or air bubble escape.
Disposable made of 1.4435 (316L) and polycarbonate. Fully traceable
cGMP compliance. One sensor fits four line sizes: ¹⁄₈ to 1"".
Transmitter features
Full access to process and diagnostic information –
numerous, freely combinable I/Os and Ethernet. Reduced complexity
and variety – freely configurable I/O functionality. Integrated
verification – Heartbeat Technology.
Remote version with up to 4 I/Os. Backlit display with touch
control and WLAN access. Standard cable between sensor and
transmitter.
Nominal diameter range
¹⁄₈"" to 1""
Wetted materials
Measuring tubes: Stainless steel 1.4435, 316L
Hose connection nipple: Makrolon Rx 1805 polycarbonate
Measured variables
Mass, density, temperature
Max. measurement error
Mass flow (liquid): ±0.5%
Measuring range
0 to 75 kg/h (0 to 165,3 lb/min)
Max. process pressure
6 bar (87 psi)
Medium temperature range
3 to 60°C (37.4 to 140°F)
Ambient temperature range
5 to 40°C (41 to 104°F)
Transmitter housing material
Aluminum, AlSi10Mg, coated
Degree of protection
Transmitter: IP66/67, Type 4X enclosure
Sensor: IP54
Display/Operation
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Outputs
""4 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output""
Inputs
Status input
4-20 mA input
Digital communication
Modbus RS485, PROFINET over Ethernet-APL
Power supply
AC 100 to 230 V / DC 24 V (non-hazardous area)
Product safety
CE, C-tick, EAC marking
Functional safety
Functional safety according to IEC 61508, applicable in
safety-relevant applications in accordance with IEC 61511
Hygienic approvals and certificates
cGMP compliance, ASME BPE, BPOG, FDA"
|