| Sign In | Join Free | My carsrow.com |
|
| Categories | Patient Monitor Parts |
|---|---|
| Brand Name: | Mindray |
| Model Number: | 050-005596-00 |
| MOQ: | 1 |
| Payment Terms: | T/T(wire transfer),Western Union,Paypal |
| Supply Ability: | 10 |
| Delivery Time: | 5-8 work days |
| BRAND: | Mindray |
| PRODUCT NAME: | VCP protection board |
| WARRANTY: | 90 Days |
| CONDITION: | In Good Working Order |
| MATERIAL: | Plastic And Metal |
| Model: | 050-005596-00 |
| MOQ: | One Piece |
| IN STOCK: | Yes |
| PAYMENT TERMS: | T/T(wire transfer), Western Union, Paypal |
| ADVANTAGE: | Original |
| TYPE: | Mindray SV600-800 |
| FUNCTIONALITY: | Good |
| Company Info. |
| China World Technology Medical Equipment Service Group |
| Verified Supplier |
| View Contact Details |
| Product List |
Mindray SV600-800 VCP protection board 050-005596-00 used with good condition patient monitor parts
Brief Introduction
VCP stands for Valve and Circuit Protection. The VCP protection board 050-005596-00 is a critical interface and safety hub between the electronic and pneumatic systems within the SV600/SV800 ventilator. Its core responsibility is to monitor and control the power supply to multiple critical solenoid valves within the ventilator, preventing potential damage caused by overcurrent or short circuits.
Core Functions and Operating Principles
1. Overcurrent Protection: This is its most basic and critical function. Ventilators use solenoid valves to precisely control the direction, pressure, and flow of gas. Frequent opening and closing of these valves can generate large transient currents due to electrical faults. The VCP protection board has built-in sophisticated detection circuitry. If the current flowing to any valve exceeds a safe threshold, it immediately shuts off the power supply to that circuit to prevent the fault from escalating.
2. Drive and Distribution: This board receives low-power control signals from the main control board and converts them into high-power currents capable of driving high-power solenoid valves. It acts as a "power amplifier" and "smart distribution board," safely and accurately distributing power to the various valves requiring operation.
3. Fault Feedback: When the protection board triggers the overcurrent protection, it sends a fault signal to the ventilator's main control system. The system immediately detects the anomaly, displays an error code on the touchscreen, and triggers an alarm to alert clinical engineers or technicians for repairs.
4. System Isolation: By limiting potential circuit failures to the VCP protection board itself or its downstream valve components, it effectively protects the more expensive and core main control board.
Specification
| Brand name | Mindray |
| Model Number | 050-005596-00 |
| Product Name | VCP protection board |
| MOQ | 1 Piece |
| Condition | Used in Good Working |
| Warranty | 90 Days |
| Delivery Method | DHL ,Fedex ,UPS |
| Inventory | In stock |
| Payment Terms | Full Before Shipment |
| Features | Professional, reliable,Economic |
| Stock Situation | Stock available |
| Packing | Carton |
| Delivery | 3-5 Working Days |
| Method of Transport | Expressage |
| Use for | Mindray SV600-800 |
Product Details Picture

Why is it so important?
1. Ensure device safety: Without its protection, a short circuit in a solenoid valve could cause the entire main control board to burn out, resulting in catastrophic equipment failure and costly repairs.
2. Ensure patient safety: Improper ventilator airway control can directly impact the patient's ventilation quality. By ensuring the proper functioning of each valve, the VCP protection board indirectly ensures that the airflow received by the patient is accurate, stable, and in accordance with the physician's prescribed parameters.
3. Improve device availability: Rapid fault diagnosis and isolation enable engineers to quickly locate the problem, shortening repair time and enabling the device to be returned to clinical use more quickly.
Common Faults and Troubleshooting
1. The VCP protection board itself is a solid-state electronic
component and is generally very durable. However, it may become a
concern in the following situations:
2. Repeated fuse burnout: If the device is frequently reported for repair and the fuse blows again shortly after replacement, it is likely that a driver module on the VCP protection board is damaged, causing persistent overcurrent.
3. Specific valve failure: If the ventilator reports a valve failure, but the problem persists after replacing the valve, the source of the problem is likely in the power path from the VCP protection board to the valve.
4. Visible physical damage: In rare cases, the board may show scorch marks, bulging capacitors, or burned chips. These are clear signs that the board needs to be replaced.
If you are interested in the Mindray SV600-800 VCP protection board 050-005596-00 used with good condition patient monitor parts, please feel free to contact me, looking forward to your inquiry.
|