| Sign In | Join Free | My carsrow.com |
|
| Categories | Fiber Optic Thermometer |
|---|---|
| Brand Name: | Japanese sensor |
| Model Number: | LTH1 series |
| Certification: | CE |
| Place of Origin: | Japan |
| MOQ: | 1pieces |
| Payment Terms: | T/T |
| Supply Ability: | 100 pieces / 30 days |
| Delivery Time: | 15~20 days |
| Temperature range: | [1][2][3] 50 ~400°C/[4][5] 400~900°C/[5] 650~1500°C |
| Effective wavelength:: | [1][2][3] 3.0-5.0μm[4][5][6] 0.8-1.6μm |
| Sensing elements:: | [1][2][3] InAsSb [4][5][6] InGaAs |
| Target:: | Red laser scanning width Angle 2 points |
| Power supply voltage:: | 24VDC, 0.5A Max |
| Cable length (standard) :: | 2 minutes |
| Company Info. |
| Shenzhen Wanyi Technology Co., LTD |
| Verified Supplier |
| View Contact Details |
| Product List |
Linear sensor thermometer-Don't miss the moving measurement object
The linear sensor thermometer developed by Japanese sensors,
equipped with 46 sensors arranged in a row, is a thermometer
capable of simultaneously measuring multiple points on a straight
line.
It can be measured at 1khz(1ms for each sensor) at any time. You
can measure any moving object. (MAX150Hz production line Scanner
Measure multiple points on a straight line simultaneously
Don't miss the moving measurement object
• Analog output and alarm output can be set for each sector
• Compact size
• Use the attached software for image confirmation and data saving

Product Model: [1] LTH1-CNN0400-0120H0.6-046S
[2] LTH1-CNN0400-0300H1.9-046S
[3] LTH1-CNN0400-0700H006-046S
[4] LTH1-PNN0400-0450H1.4-046S
[5] LTH1-PNN0400-0500H2.8-046S
[6] LTH1-PNN0650-0500H2.8-046S
Temperature range: [1][2][3] 50 ~400°C
[4][5] 400~900°C
[5] 650~1500°C
Effective wavelength: [1][2][3] 3.0-5.0μm
[4][5][6] 0.8-1.6μm
Sensing elements: [1][2][3] InAsSb
[4][5][6] InGaAs
Standard target size: [1] Scanning width: 28mm
[2] Scanning width: 90mm
[3] Scanning width: 280mm
[4] Scanning width: 64mm
[5][6] Scanning width: 130mm
Target: Red laser scanning width Angle 2 points
Response time (variable, with smoothing function) : Scanning speed: 1kHz
Preheating time: 5 minutes
Analog output (non-isolated) Output type (switch) : 8-channel analog output (isolated) 0-20mA, 4-20mA, 0-5V, 0-10V,
mV/°C, 10mV/°C
RS232C output (compliant with RS232C standard, non-isolated) : * Note: Linear sensor thermometer: RS485 output (isolated) output
swing width: approximately ±4V
Communication speed: 1200bps to 6,000,000 BPS (6Mbps)
Alarm output (non-isolated) : Photodiode relay 2-point DC 27V, 0.1A hysteresis setting width:
0-99.9°C
Peak hold: Peak hold/valley hold/sampling hold
Emissivity correction: Warranty range 0.3 to 1.0
Set the range from 0.050 to 1.000 (set the resolution to 0.001)
It has a reflection correction function
Sensor calibration function: span; 0.500 ~ 2.000
Zero point -50 to +50°C (°F)
Ambient temperature and humidity: 0 to 50°C (Storage ambient temperature: -15 to 70°C)
30-85% RH (no condensation)
Power supply voltage: 24V DC, 0.5A Max
Cable length (standard) : 2 minutes
|