product name: Fractional CO2 Laser
technology: Medical CO2 Laser Machine
function: Dermatology CO2 Laser
Working Mode: Single pulse, Continuous pulse, Repeated pulse
Laser Type: Metal Tube
Laser Wavelength: 10600nm
Output Power: 60W
Input Power: 450VA
Operation Modes: Pulsed, Ultra Pulsed, Continuous
Pulse Width: 0.02–0.99s
Pulse Duration: 1–100μs
Scan Patterns: Triangle, Square, Rectangle, Diamond, Line, Round
Beam Divergence: 4mrad
Focused Spot Diameter: 120–240μm
Aiming Beam: Infrared Ray (630–650nm, <5mW)
Beam Delivery: 7-joint articulated arm, 360° rotation
Cooling System: Internal circulation cooling
Display Screen: True color LCD touch screen
Operation System: Microcomputer control
Input Voltage: AC220V ±10%, 50Hz
Probes: Scanner probe, Vaginal probe, Surgical probe
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Medical Fractional CO2 Laser Device With Vaginal Probe For Gynecology Rejuvenation Skin Tightening And Pigmentation Therapy

Gynecology CO2 Laser System

1. What is CO₂ Laser Technology?

The CO₂ laser is a high-energy system that emits light at a wavelength of 10600nm, which is strongly absorbed by water in biological tissues. Because human skin and mucosa are rich in water, this laser is highly effective in cutting, vaporizing, and coagulating soft tissue with excellent precision.

The device uses fractional scanning technology and different probes to adapt to dermatology, gynecology, and surgical procedures.

  • In dermatology, the fractional CO₂ laser creates microthermal zones in the skin, stimulating collagen regeneration and improving skin texture, wrinkles, scars, and pigmentation.

  • In gynecology, the CO₂ vaginal probe promotes mucosal regeneration, improves tissue elasticity, and restores vaginal health.

  • In surgery, the precise cutting ability allows minimally invasive operations with reduced bleeding and faster healing.

This combination of applications makes it a versatile solution for clinical and cosmetic needs.

2. Applications

Dermatology

  • Skin resurfacing and rejuvenation

  • Reduction of fine lines and wrinkles

  • Scar improvement (acne scars, surgical scars, burn scars)

  • Pigmentation treatment

  • Skin tightening and pore reduction

Gynecology

  • Vaginal tightening and rejuvenation

  • Improvement of dryness and laxity

  • Postpartum tissue restoration

  • Supportive therapy for mild incontinence

Surgery

  • Cutting and vaporization of soft tissue

  • Coagulation to reduce bleeding

  • Precise excision with minimal damage to surrounding tissue

3. Product Parameters

ParameterSpecification
Working ModeSingle pulse, Continuous pulse, Repeated pulse
Laser TypeMetal Tube
Laser Wavelength10600nm
Output Power60W
Input Power450VA
Operation ModesPulsed, Ultra Pulsed, Continuous
Pulse Width0.02–0.99s
Pulse Duration1–100μs
Scan PatternsTriangle, Square, Rectangle, Diamond, Line, Round
Beam Divergence4mrad
Focused Spot Diameter120–240μm
Aiming BeamInfrared Ray (630–650nm, <5mW)
Beam Delivery7-joint articulated arm, 360° rotation
Cooling SystemInternal circulation cooling
Display ScreenTrue color LCD touch screen
Operation SystemMicrocomputer control
Input VoltageAC220V ±10%, 50Hz
ProbesScanner probe, Vaginal probe, Surgical probe

4. Product Features

  • Versatile Probes: Equipped with scanner, gynecological, and surgical handpieces.

  • Fractional Scanning: Adjustable scan patterns and spot sizes for tailored treatments.

  • Precision Cutting: Ultra-pulsed mode for delicate surgical applications.

  • Smart Control System: Microcomputer-based, user-friendly interface.

  • Efficient Cooling: Built-in circulation ensures stable performance.

  • Ergonomic Design: 7-joint articulated arm provides flexibility and accuracy.

5. Treatment Steps

Dermatology (fractional resurfacing)

  1. Cleanse the treatment area.

  2. Apply topical anesthesia if needed.

  3. Select scan pattern, energy level, and pulse duration.

  4. Deliver fractional CO₂ laser to target area.

  5. Apply cooling gel or soothing mask after treatment.

Gynecology

  1. Gynecological evaluation and patient preparation.

  2. Apply local anesthesia or numbing gel if required.

  3. Insert vaginal probe gently.

  4. Deliver laser energy in fractional mode for mucosal stimulation.

  5. Patient may resume normal activity within 1–2 days.

Surgery

  1. Prepare surgical site under aseptic conditions.

  2. Adjust laser mode (pulsed, continuous, or ultra-pulsed).

  3. Perform incision, vaporization, or coagulation as needed.

  4. Minimal bleeding due to coagulation effect.

  5. Postoperative dressing and care.

6. Pre-Treatment Guidelines

  • Avoid sun exposure and tanning for at least 2 weeks before treatment.

  • Do not use retinoids or exfoliating agents 1 week prior.

  • Inform the doctor about any medications or medical history.

  • For gynecology, ensure no active infection or menstruation period.

7. Post-Treatment Care

  • Apply prescribed soothing ointments to the treated area.

  • Avoid hot baths, sauna, and strenuous exercise for 1 week.

  • Keep the treated skin clean and moisturized.

  • Use sunscreen daily to prevent pigmentation.

  • For gynecological procedures, avoid activity for 5–7 days.

8. Contraindications

  • Pregnancy and breastfeeding

  • Severe systemic diseases (uncontrolled diabetes, cardiovascular conditions)

  • Active infections or open wounds at the treatment site

  • History of keloid formation or abnormal scarring

  • Blood clotting disorders or use of anticoagulants

Gynecology CO2 Laser System

Quality Medical Fractional CO2 Laser Device With Vaginal Probe For Gynecology Rejuvenation Skin Tightening And Pigmentation Therapy for sale
Send your message to this supplier
 
*From:
*To: Changsha GOMECY Electronics Limited
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0