7ETO-100 Ethylene Oxide Gas Sensor For Medical Device Sterilization Pharmaceutical Manufacturing

Categories Gas Sensor
Model Number: 7ETO-100
Place of Origin: CN
MOQ: 1PCS
Price: Negotiable
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 5000PCS
Delivery Time: 5-8 work days
Packaging Details: Standard packaging
Resolution: ≤ 1 ppm
Response Time (T90): ≤ 30 seconds
Recovery Time (T10): ≤ 60 seconds
Operating Temperature: -10°C to +50°C
Operating Humidity: 15%~90% RH
Atmospheric Pressure: 86~106 kPa
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

7ETO-100 Ethylene Oxide Gas Sensor For Medical Device Sterilization Pharmaceutical Manufacturing


7ETO-100 Ethylene Oxide Gas Sensor For Medical Device Sterilization Pharmaceutical Manufacturing


The 7ETO-100 operates on the electrochemical detection principle, leveraging a three-electrode cell immersed in an electrolyte solution:


  1. Gas Diffusion: Ethylene oxide gas in the environment diffuses through a porous membrane (gas-permeable membrane) into the sensor’s internal electrolyte.
  2. Electrochemical Reaction: At the working electrode (cathode), ETO undergoes oxidation, producing electrons, protons (H⁺), and harmless byproducts (e.g., CO₂, H₂O).
  3. Current Generation: The electrons generated by the oxidation reaction flow through an external circuit to the counter electrode (anode), creating a measurable electrical current. The magnitude of this current is linearly proportional to the concentration of ETO in the sample gas (per Faraday’s Law of Electrolysis).
  4. Stability Maintenance: The reference electrode provides a stable voltage reference, preventing drift in the working electrode’s potential and ensuring long-term measurement accuracy.

4. Typical Applications

The 7ETO-100 is engineered for scenarios requiring ETO monitoring, with core use cases including:

4.1 Medical Sterilization Industry

Ethylene oxide is widely used to sterilize heat-sensitive medical devices (e.g., surgical instruments, syringes, implants). The 7ETO-100 is integrated into:


  • Sterilization Chamber Monitors: Real-time tracking of ETO concentration during the sterilization cycle to ensure effective microbial inactivation.
  • Post-Sterilization Ventilation Systems: Detection of residual ETO in sterilized equipment or exhaust air, ensuring levels meet safety standards (e.g., ≤ 1 ppm for personnel exposure) before devices are used or air is released.

4.2 Chemical & Pharmaceutical Manufacturing

In facilities producing ETO or using ETO as a raw material (e.g., for ethylene glycol synthesis, detergent production):


  • Fixed-Point Leak Detectors: Installation near pipelines, valves, or reaction vessels to trigger alarms if ETO leaks occur (preventing toxic exposure or fire risks).
  • Process Control Systems: Monitoring ETO concentration in reaction streams to optimize production efficiency and ensure product quality.

4.3 Environmental & Occupational Safety

  • Portable Gas Detectors: Used by maintenance workers, laboratory staff, or emergency responders to monitor personal exposure to ETO in confined spaces (e.g., sterilization rooms, chemical storage areas) or during leak investigations.
  • Indoor Air Quality (IAQ) Monitors: In facilities where ETO may accumulate (e.g., hospitals, pharmaceutical plants), the sensor ensures indoor ETO levels comply with occupational health regulations (e.g., OSHA’s permissible exposure limit (PEL) for ETO: 1 ppm over an 8-hour workday).

4.4 Food Processing (Optional)

In some food sterilization applications (e.g., low-temperature sterilization of packaged foods), the 7ETO-100 monitors residual ETO to ensure food safety and compliance with global food standards.

5. Installation & Operation Guidelines

5.1 Installation Notes

  • Location: Mount the sensor in areas where ETO is likely to accumulate (e.g., near sterilization chambers, ETO storage tanks) or where personnel frequent. Avoid direct sunlight, extreme temperatures, or high-humidity (condensing) environments.
  • Gas Inlet: For diffusion-type sensors, ensure unobstructed air flow around the sensor (minimum 5 cm clearance from walls/obstacles). For pump-type sensors, connect the gas inlet tube to the sampling point (tube length ≤ 2 meters to avoid response delay).
  • Wiring: Follow the sensor’s pinout diagram (provided in the datasheet) for power and signal connections. Use shielded cables for analog signals to reduce electromagnetic interference (EMI).

5.2 Calibration

  • Initial Calibration: Perform a two-point calibration (zero calibration with clean air, span calibration with a known ETO concentration gas) before first use.
  • Routine Calibration: Recalibrate every 3–6 months (or as required by local regulations) to maintain accuracy. Calibration gas should be certified (NIST-traceable or equivalent) with a concentration close to the sensor’s full scale (e.g., 80 ppm for a 0–100 ppm sensor).

5.3 Maintenance

  • Cleaning: Periodically wipe the sensor’s exterior with a dry, lint-free cloth. Do not use solvents or water on the gas inlet membrane.
  • Replacement: Replace the sensor if: (1) response time exceeds 60 seconds, (2) accuracy deviates by >10% of FS after calibration, or (3) the sensor reaches its rated lifespan.

6. Safety Precautions

  • Toxic Gas Risk: Ethylene oxide is toxic and carcinogenic—always wear appropriate PPE (e.g., gas mask, gloves) when handling ETO or performing sensor maintenance in potentially contaminated areas.
  • Flammability: ETO is flammable (explosion limit: 3%–100% by volume in air)—avoid installing the sensor near open flames, sparks, or high-temperature surfaces.
  • Sensor Handling: Do not disassemble the sensor (risk of electrolyte leakage, which may cause skin irritation). Dispose of old sensors in accordance with local hazardous waste regulations.

Parameter Category

Parameter Name

Specification

Unit

Remarks

Target Gas & Sensing PrincipleTarget GasEthylene Oxide (EO/ETO)-Specialized for EO detection; not compatible with other toxic gases
Sensing PrincipleElectrochemical (Three-electrode Structure: Working/Counter/Reference Electrodes)-Ensures high selectivity and low signal drift
Measurement PerformanceDetection Range0 ~ 100ppmCustom ranges (0~50 ppm, 0~200 ppm) available upon request
Resolution≤ 0.1ppmMinimum detectable concentration change
Accuracy±5% FS (Full Scale) or ±2 ppm, whichever is larger-Tested under standard conditions (25℃, 1 atm, 50% RH)
Response Time (T90)≤ 30SecondsTime to reach 90% of stable output signal
Recovery Time (T10)≤ 60SecondsTime to drop to 10% of stable output signal
Electrical CharacteristicsPower Supply Voltage5.0 ± 0.2V (DC)Regulated power required; avoid overvoltage
Operating Current≤ 50mATypical value during continuous operation
Output Signal TypeOption 1: Analog (4 ~ 20 mA DC); Option 2: Analog (0 ~ 5 V DC); Option 3: Digital (UART/I2C)-Select output type when ordering
Signal Linearity≥ 99%-Factory-calibrated; no external linearization needed
Environmental AdaptabilityOperating Temperature Range-10 ~ 50Avoid condensation or extreme temperature fluctuations
Storage Temperature Range-20 ~ 60Store in dry, dust-free environment
Operating Humidity Range15 ~ 90% RHNon-condensing; humidity >90% RH may affect accuracy
Atmospheric Pressure Range86 ~ 106kPaSuitable for most low-altitude industrial/medical sites
Mechanical & Physical SpecsHousing MaterialOption 1: ABS Plastic (Standard); Option 2: 316L Stainless Steel (Harsh Environment)-Stainless steel option resists corrosion
Gas Intake ModeOption 1: Diffusion (Passive); Option 2: Pump-driven (Active)-Diffusion for general use; pump-driven for long-distance sampling
Overall Dimensions (L×W×H)45 × 30 × 20 (ABS version); 50 × 35 × 25 (Stainless Steel version)mmExcludes connector/probe; refer to 2D drawing for exact size
Weight≤ 30 (ABS version); ≤ 80 (Stainless Steel version)gNet weight (excluding cables/fittings)
Lifespan & MaintenanceTypical Operational Lifespan≥ 2YearsUnder continuous operation in clean air (EO concentration < 1 ppm); lifespan shortens in high-concentration EO
Calibration Interval3 ~ 6MonthsRecommended for maintaining accuracy; use NIST-traceable EO calibration gas


Quality 7ETO-100 Ethylene Oxide Gas Sensor For Medical Device Sterilization Pharmaceutical Manufacturing for sale
Send your message to this supplier
 
*From:
*To: ShenzhenYijiajie Electronic Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0