The TE Connectivity LUMAWISE Endurance N Control Base and Cover is designed for roadway and area lighting applications, utilizing the ANSI C136.41 interface. It features pre-installed contacts and a molded gasket seal for protection. The base assembly can be supplied with either 2 or 4 dimming signal contacts, and the customer is responsible for providing and installing the light controller electronics. The cover is available separately.
| Specification | Details |
| Operating Temperature Range | -40 to 85C [-40 to 185F] |
| PC Board Placement | Thru-hole solder tails. Pattern available on TE Connectivity customer drawing. |
| Soldering Guidelines | Acceptable hand-soldering techniques. Conforms to IPC-A-610 and IPC J-STD-001. |
| Cover Assembly | Align cover key with base keyway. Press cover squarely onto base. Ensure all 6 latches are fully engaged. Use of assembly fixture and press recommended. |
| Vented Base Assembly | Ensure external/internal features do not obstruct vent areas. Minimum 1mm gap recommended between vent and adjacent components. |
| Mounting Location & Orientation | Receptacle on top of fixture away from direct light. Orient North indicator North if possible. |
| Workmanship | Control base must be undamaged. Inspect for proper, undamaged, unbent contacts. Ensure cover latches are fully engaged. |
| Contact Connections | Alignment and mating to receptacle per ANSI C136.41-2013. Color labels correspond to receptacle wire color format. |
| Mating/Un-mating | Align base blades with receptacle power circuits (neutral blade is larger for polarization). Push downward until bottomed. Twist clockwise to lock. Twist counter-clockwise to un-mate. |
| Replacement & Repair | Contacts and control base are not repairable. Replace damaged or defective units. Assembled base and cover are not repairable without destructive means. |
|