| Sign In | Join Free | My carsrow.com |
|
| Categories | Plastic Testing Equipment |
|---|---|
| Temperature resolution: | 0.01℃ |
| Certification: | ISO,CE |
| Product volume: | 100L |
| Temperature deviation: | ±2.0℃ |
| Supply Ability: | 5 units per month |
| Power supply voltage: | AC220V ±10%, 50Hz |
| Payment Terms: | T/T,Cash,L/C |
| power: | 600W |
| Place of Origin: | China |
| Temperature fluctuations: | ±0.5℃ |
| Equipment weight: | 350KG |
| Price: | Negotiate |
| Packaging Details: | Wooden cases |
| Temperature range: | -40 ℃ to+150 ℃ |
| Temperature uniformity: | ≤2.0℃ |
| Delivery Time: | 10 Work Days |
| Voltage: | 220V |
| Brand Name: | CHENGFENG |
| Material: | Stainless steel |
| MOQ: | 1 Set |
| External dimensions: | 780 * H1600 * D1450mm |
| Company Info. |
| Dongguan Chengfeng Testing Equipment Co., Ltd |
| Verified Supplier |
| View Contact Details |
| Product List |
Meets standard: IEC61730-2 MST26
Test objective: To evaluate the conductive material of the external insulation
layer of the component. In the event of a reverse current fault and
before the overcurrent protector installed in the circuit
disconnects, the battery and interconnect bars of the component
will be forced to generate heat to consume energy. This experiment
is used to determine the component's ability to withstand ignition
and fire in this state.
Features:
-The maximum current that can be provided to the component is 100A
The magnitude of the reverse current can be set and monitored in
real-time (optional)
-Equipped with historical data query function (optional)
-Export all data in EXCEL format (optional)
-Temperature measurement range: -20 ℃~200 ℃ Accuracy: 0.5 ℃
(optional)
-Pine boards can provide third-party thermal conductivity reports
Input:
voltage: three-phase 380 VAC ± 15%
Frequency: 47~63Hz
output;
Voltage: 0~100V (customizable)
Current: 0~100A (customizable)
Power: 10KW (customizable)
Current accuracy: Steady current CC: ≤ 0.05%+0.5% F · S (set value)
Voltage accuracy: Voltage stabilization CV: ≤ 0.05%+0.3% F · S (set
value)
Efficiency: ≥ 90% (standard AC input, full load)
output display
Display mode: Four digit LED digital display
Display resolution: 4-digit display accuracy
Instrument accuracy: ± 0.1%
Remote simulation monitoring
Simulation control USB/LAN






|