| Brand Name: | BAXIT | 
| Model Number: | BXT-AAS8H | 
| Place of Origin: | china | 
| MOQ: | 1 | 
| Price: | USD 5930-7580/unit | 
| Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram | 
| Supply Ability: | 1000units | 
| Delivery Time: | 3-5working days | 
| Packaging Details: | wooden box | 
| Classification: | Flame type(8Lamp Positions) | 
| Model: | BXT-AAS8H | 
| Detector: | Hamamatsu Photomultiplier Tube from Japan | 
| wavelength range: | (190-900)nm | 
| Wavelength indication error: | ≤±0.1nm | 
| Wavelength repeatability: | ≤±0.025nm | 
| Baseline drift: | 0.001ABS/30min(Static) 0.003ABS/15min(Dynamic) | 
| Light source system: | Rotary turret-type fully automatic switching lamp holder | 
| Element lamp Lighting mode: | 400Hz, 1/4 duty cycle pulse is on | 
| Monochromator: | Czerny-Turner Enhanced type | 
| Grating line density: | 1800 | 
| Spectral bandwidth: | 0nm、0.1nm、0.2nm、0.4nm、1.0nm、2.0nm Multi-gear automatic switching | 
| Atomizer: | Flame atomizer | 
| Flame atomization system: | Standard equipment | 
| Burner: | 0.5mmx100mmAll-titanium combustion head | 
| Sprayer: | Metal sleeve high-efficiency glass spray nozzle | 
| Atomization chamber: | Corrosion-resistant all-plastic atomization chamber | 
| Repetition: | RSD≤0.7% | 
| Detection limit: | (Cu)<0.006ug/ml | 
| Safety protection: | It has multiple safety protection functions, including alarm for acetylene leakage and system shutdown. | 
| Sample size: | 1-99 | 
| Result output: | Multi-format data storage and print output | 
| Communication interface: | RS232, USB expansion interface | 
| Host machine size: | 1000x400x470mm | 
| Weight(kg): | 75 | 
| Company Info. | 
| Shanghai Glomro Industrial Co., Ltd. | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
Atomic Absorption Spectrophotometer
Atomic absorption spectrophotometer can be widely applied in various industries such
as geology, metallurgy, medicine, chemical engineering, petroleum, agriculture, environmental
protection and commodity inspection. The application of it for the analysis of trace and ultra-trace
elements has gradually shifted from inorganic chemistry to organic chemistry in recent years.

Working principle
The characteristic spectral radiation of the element to be measured is emitted by the light
source and absorbed by the ground-state atoms of the element to be measured in the vapor
of the sample produced by the atomizer such as a flame or graphite furnace. The content of
the element to be measured is determined by measuring the amount of the characteristic
spectral radiation absorbed.
| Classification | Flame type (4,6,8Lamp Positions) | Flame Graphite Integrated Machine (4,6Lamp Positions) | Fully automatic flame graphite integrated machine (8Lamp Positions) | 
| Model | BXT-AAS4H BXT-AAS6H BXT-AAS8H | BXT-AAS4HS BXT-AAS6HS | BXT-AAS8HS-P | 
| Detector | Hamamatsu Photomultiplier Tube from Japan | ||
| wavelength range | (190-900)nm | (185-900)nm | |
| Wavelength indication error | ≤±0.1nm | ||
| Wavelength repeatability | ≤±0.025nm | ||
| Baseline drift | 0.001ABS/30min(Static) 0.003ABS/15min(Dynamic) | ||
| Light source system | Rotary turret-type fully automatic switching lamp holder | ||
| Element lamp Lighting mode | 400Hz, 1/4 duty cycle pulse is on | ||
| Monochromator | Czerny-Turner Enhanced type | ||
| Grating line density | 1800 | ||
| Spectral bandwidth | 0nm,0.1nm,0.2nm,0.4nm,1.0nm,2.0nm Multi-gear automatic switching | ||
| Atomizer | Flame atomizer | ||
| Flame atomization system | Standard equipment | ||
| Burner | 0.5mmx100mmAll-titanium combustion head | ||
| Sprayer | Metal sleeve high-efficiency glass spray nozzle | ||
| Atomization chamber | Corrosion-resistant all-plastic atomization chamber | ||
| Repetition | RSD≤0.7% | ||
| Detection limit | (Cu)<0.006ug/ml | ||
| Safety protection | It has multiple safety protection functions, including alarm for acetylene leakage and system shutdown. | ||
| Graphite Furnace Atomic Absorption System | No | Standard configuration | |
| Detection limit | No | 1.5pg | |
| Precision | No | ≤3% | |
| Heating temperature range | No | Room temperature-3000℃ | |
| Heating speed | No | 2000 degrees per second | |
| Temperature control accuracy | No | 1% | |
| Heating conditions setting | No | 11 step, ramp temperature rise, stepwise temperature rise, maximum power temperature rise, temperature rise monitoring opposite-side system | |
| Safety protection | No | Pressure system failure protection, cooling system failure protection, real-time power monitoring | |
| Background correction (deuterium lamp) | No | When using 1ABS, the value should be ≥ 60 times. | |
| Background correction | No | When using 1ABS, the value should be ≥ 60 times. | |
| Automatic sample introduction system | No | 85 channels, automatic calibration curve configuration, automatic dilution function, high-precision injection | |
| Sample size | 1-99 | ||
| Result output | Multi-format data storage and print output | ||
| Communication interface | RS232, USB expansion interface | ||
| Host machine size | 1000x400x470mm | 1030x430x400mm | |
| Weight(kg) | 75 | 120 | 130 | 
Applicable scenarios



Product detail illustration



|   | 
 Lab Device Touch Screen FP640 Digital Flame Photometer For K Na Of Agricultural Fertilizers Or Soil
                                                                                        
                                                        
                        
                        
                        
                                                            Lab Device Touch Screen FP640 Digital Flame Photometer For K Na Of Agricultural Fertilizers Or Soil
                                                    
                        
                     FP640 Laboratory Touch Screen Flame Photometer Metal Analyzer Na K Flame Photometer Spectrophotometer
                                                                                        
                                                        
                        
                        
                        
                                                            FP640 Laboratory Touch Screen Flame Photometer Metal Analyzer Na K Flame Photometer Spectrophotometer
                                                    
                        
                     7 Inch LCD Touch Screen Flame Spectrophotometer BXT-FP640 In Field Of Agricultural Fertilizer Soil Cement
                                                                                        
                                                        
                        
                        
                        
                                                            7 Inch LCD Touch Screen Flame Spectrophotometer BXT-FP640 In Field Of Agricultural Fertilizer Soil Cement
                                                    
                        
                     Precision 0.0001g Laboratory Testing Equipment with Electromagnetic Force Sensor and 200g Standard Calibration Weight
                                                                                        
                                                        
                        
                        
                        
                                                            Precision 0.0001g Laboratory Testing Equipment with Electromagnetic Force Sensor and 200g Standard Calibration Weight
                                                    
                        
                     Digital Flame Spectrometer Lab Flame Photometer For K Na Ca Ba Li Analysis
                                                                                        
                                                        
                        
                        
                        
                                                            Digital Flame Spectrometer Lab Flame Photometer For K Na Ca Ba Li Analysis
                                                    
                        
                     BXT 0.0001g 0.1mg High Precision Electronic Analytical Digital Balance FA Series Analytical Balance
                                                                                        
                                                        
                        
                        
                        
                                                            BXT 0.0001g 0.1mg High Precision Electronic Analytical Digital Balance FA Series Analytical Balance
                                                    
                        
                     Flame Photometer Portable BXT- FP640 Spectrophotometer Optical Instrument
                                                                                        
                                                        
                        
                        
                        
                                                            Flame Photometer Portable BXT- FP640 Spectrophotometer Optical Instrument
                                                    
                        
                     100g0.1mg Analytical Balance 0.0001g Balance Weighing Balance For Laboratory
                                                                                        
                                                        
                        
                        
                        
                                                            100g0.1mg Analytical Balance 0.0001g Balance Weighing Balance For Laboratory
                                                    
                        
                     Stability Automatic FP6430 K Na Li Digital Flame Photometer
                                                                                        
                                                        
                        
                        
                        
                                                            Stability Automatic FP6430 K Na Li Digital Flame Photometer
                                                    
                        
                     BXT FA1204 Sensitive Precision Digital Analytical Lab Weighing Scale In Grams For Science Laboratory  0.0001g 0.1mg 1mg
                                                                                        
                                                        
                        
                        
                        
                                                            BXT FA1204 Sensitive Precision Digital Analytical Lab Weighing Scale In Grams For Science Laboratory  0.0001g 0.1mg 1mg