Sign In | Join Free | My carsrow.com
carsrow.com
Products
Search by Category
Home > Rubber Projects >

XHGX507C Grey Underground Utilities Locator

Categories Cable Route Tracer
Brand Name: XZH TEST
Model Number: XHGX507C
Place of Origin: Shaanxi
MOQ: 1unit
Price: EXW 2105
Payment Terms: T/T
Supply Ability: 100 unit per month
Packaging Details: wooden packaging
Color: Grey
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

XHGX507C Grey Underground Utilities Locator

Product description:

The intelligent cable pipeline detector , also known as pipeline tester or path tester, is a path detection instrument with strong comprehensive performance. It has multiple functions such as

pipeline path detection, cable identification, fault finding , etc. The instrument consists of a transmitter, a transmitting current clamp, a receiver , a receiving flexible current clamp, a connecting test line, and an A - frame (optional) .

The intelligent cable pipeline detector can be used for path detection, pipeline census and depth measurement of metal pipelines and underground cables in a trench less environment. The instrument uses a variety of filtering technologies, has anti-interference capabilities, can accurately locate and measure depth, and is suitable for the detection and patrol of various underground metal pipelines, pipeline management and maintenance, municipal planning and construction, power supply and other departments. It is one of the necessary instruments for pipeline maintenance units. This function is achieved by the cooperation of a signal transmitter, a receiver, a signal transmission clamp and a connecting test line.


Technical data:

Transmitter:

FunctionMultiple frequency signal transmission modes
power supply10.8V large capacity rechargeable lithium battery
Output methodDirect connection method, coupling method, induction method

Output frequency
640Hz, 1.28kHz, 2.56kHz, 3.20kHz, 4.09kHz, 8.19kHz, 10.2kHz, 32.7kHz,
65.6kHz, 81.9kHz, 197kHz
Output ModeAutomatic identification, automatic identification according to different accessories
Output Power15W max, 9 levels adjustable
impedanceFully automatic real-time impedance matching and protection function
Direct output voltage150Vpp max
Circuit ProtectionWith overload and short circuit protection
liquid crystal5- inch LCD color screen
touchYes, capacitive touch
Instrument sizeAbout 320mm (length) × 275mm (width) × 145mm ( height)


Receiver:


Function
Pipeline detection (cable position tracking, direction display, depth measurement, current measurement), cable identification, A-frame fault finding (optional function)
power supply8.4V large capacity rechargeable lithium battery
Input methodBuilt-in receiving coil, flexible caliper, A -frame ( optional function)


Receiving frequency
Active detection frequencies: 640Hz , 1.28kHz , 2.56kHz , 3.20kHz , 4.09kHz , 8.19kHz , 10.2kHz, 32.7kHz, 65.6kHz, 81.9kHz, 197kHz
Power frequency passive detection frequency: 50Hz, 60Hz, 250Hz
RF passive detection frequency band: center frequencies are 32.7kHz, 65.6kHz, 81.9kHz, 197kHz
Pipeline detection modeBroad peak method, narrow peak method, valley method
Pipeline detection displayClassic positioning mode, wire cruise mode, signal distortion measurement mode


Pipeline detection range
Direct connection method: Generally, the cable length can reach 0~20 kilometers, which is mainly determined by the ground resistance, cable resistance and cable burial depth.
Coupling method: Generally, the cable length can reach 0~10 kilometers, which is mainly determined by the ground resistance, cable resistance and cable burial depth.
Cables buried less than 2m deep
Depth and CurrentReal-time display of cable depth and current value
Pipeline measurement depth0-20m

Depth Accuracy
Plane position precision positioning accuracy: Center axis position of target cable or pipeline:±5% ( burial depth 0-3m) -10% ( burial depth 3m- 20m)


True or False Tips
Eliminate interference from adjacent cables. When measuring adjacent cables, the measurement of adjacent cables can be distinguished based on the different signal strengths and measured current phases fed back by the adjacent cables. During the cable tracking process, observe the phase table.
The disk and pointer point to distinguish the tested cable from the adjacent cables
Sound InstructionsFM tone that varies with signal strength
Anti-interference displayGreen: No interference
Green: Good (results are reliable )
Red: Severe interference (results are unreliable )

Anti-interference ability
The extremely narrow receiving frequency band and unique digital processing method can fully suppress the power frequency and harmonic interference of nearby running cables and pipelines.



Interference distance
When using the coupling method and the induction method, the transmitter will generate interference within a short distance. The interference distance is related to the transmission power and frequency. The greater the power and the higher the frequency, the stronger the interference.
The minimum distance at which a receiver is not disturbed by a transmitter often requires experimental determination:
Pipeline detection: Coupling method can confirm no interference beyond 5m , induction method can confirm no interference beyond 20m Cable identification: Coupling method can confirm no interference beyond 2~5m



Cable identification
Identification method:flexible caliper intelligent identification; number of cables that can be calibrated: 1 to 20 ;
Calibration value: The current percentage of the received signal and the transmitted signal is between 75% and 135% of the calibration value, which is one of the conditions for successful identification;
Directionality: The transmitting clamp, receiving clamp and loading signal must be in the same direction, which is one of the conditions for successful identification.

Cable identification detection range
Direct connection method: can identify signals with loop resistance of 0Ω~8kΩ (usually can reach cable length of 0~20 kilometers , mainly determined by ground resistance and cable resistance)
Coupling method: can identify signals with a loop resistance of 0Ω to 1kΩ ; (generally can reach a cable length of 0~ 6cm
(mainly determined by grounding resistance and cable resistance)
liquid crystal4.3- inch LCD color screen (high brightness screen), visible in sunlight
touchYes, capacitive touch
sizeAbout 350mm (length) × 155mm (width) × 700mm ( height)
qualityAbout 2kg
Connection interfaceType-C USB port, aviation socket
Coil inner diameterφ200mm (larger diameter can be customized as needed )
Working temperature and humidity-10ºC~40ºC; below 80% Rh
Storage temperature and humidity-10ºC~50ºC; ≤95%RH, no condensation
Pressure resistanceAC2000V/rms ( before the front and rear ends of the shell)
Suitable for safety regulationsIEC61010-1 CAT III 600V, IEC61010-031, IEC61326, pollution degree 2

Quality XHGX507C Grey Underground Utilities Locator for sale
Send your message to this supplier
 
*From:
*To: Xi'an Xu&Hui Electromechanical Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0