| Sign In | Join Free | My carsrow.com | 
 | 
| Categories | Multifunction Process Calibrator | 
|---|---|
| Brand Name: | VICTOR | 
| Model Number: | VICTOR 15+ | 
| Certification: | CE | 
| Place of Origin: | CHINA | 
| MOQ: | 1pcs | 
| Price: | USD350/pc | 
| Payment Terms: | T/T, Western Union, L/C, Paypal | 
| Supply Ability: | 1000pcs available | 
| Delivery Time: | 5 to 30 days | 
| Packaging Details: | 10pcs/Carton; Carton Size: 39.5*38.5*26cm; 12KG/carton | 
| Color: | Blue and Black | 
| Size: | 205 × 95 × 42 mm | 
| Product Name: | portable temperature calibrators | 
| Model No.: | VICTOR15+ | 
| Packing Details: | 10pcs/Carton; Carton Size: 39.5*38.5*26cm | 
| Accuracy: | 0.02%+0.01% accuracy | 
| Weight: | Approx. 1100 g (including batteries) | 
| Power supply: | 4*1.5V AAA Alkaline battery | 
VICTOR 15+ V/mA Calibrator current calibrator handheld calibrator
V/mA/Pressure Calibrator
The voltage/current/pressure calibrator (the calibrator in the
following) is a handheld, battery-operated instrument that measures
and sources electrical and physical parameters.
Features:
Measure: DC-voltage, DC-current, frequency and continuity
Source: DC-voltage, DC-current, simulation transmitter, frequency
and pulse
Pressure: measuring pressure, Calibrating pressure-voltage
transmitter, Calibrating 2wire pressure transmitter, Calibrating
pressure switch;
Others features:
Specifications
General Specifications for measure
These specifications assume:
Accuracy is expressed as ± (percentage of reading + percentage of range).
| F Function | Reference | Range | Resolution | Accuracy | Remark | 
| DCV | 200mV | -20.00mV~ | 10μV | 0.02+0.02 | Input Resistance: 100MΩ | 
| 5V | -0.5000V~ | 0.1mV | 0.02+0.01 | Input Resistance: 1MΩ | |
| 50V | -5.000V~ | 1mV | 0.03+0.01 | ||
| DCmA | 50mA | -4.000mA~ | 1μA | 0.02+0.01 | Input Resistance: 5Ω | 
| FREQ | 500Hz | 3Hz~500.00Hz | 0.01Hz | ±2digit | Input Impedance:100 kΩ at least; | 
| 5KHz | 3Hz~ | 0.1Hz | |||
| 50KHz | 3Hz~50.000KHz | 1Hz | |||
| *CONT. | ≤250Ω sound | OPEN/CLOSE | Open voltage: 2.5V | 
General Specifications for Source
| Function | Reference | Range | Resolution | Accuracy | Remark | 
| DCV | 1000mV | -100.000mV~1100.000mV | 10μV | 0.02+0.01 | Maximum output current: 2mA | 
| 10V | -1.0000V~11.0000V | 0.1mV | 0.02+0.01 | Maximum output current: 5mA | |
| DCA | 20mA | 0.000mA~22.000mA | 1μA | 0.02+0.02 | External supply for simulate mA: 5V–28V | 
| FREQ | 100Hz | 1.00Hz~110.00Hz | 0.01Hz | ±2 count | Output voltage: 1~11 Vp-p (zero base waveform); | 
| 1KHz | 0.100kHz~1.100KHz | 1Hz | |||
| 10KHz | 1.0KHz~11.0KHz | 0.1KHz | |||
| PULSE | 100Hz | 1~100000cycles | 1cyc | _______ | Output voltage: 1~11 Vp-p (zero base waveform); | 
| 1KHz | |||||
| 10KHz | |||||
| LOOP | 24V | ±10% | Maximum current: 25 mA | 
Other feature:
l Temperature Coefficient: 0.1 times the applicable accuracy specification per degree ℃for 5℃ to 18℃ and 28℃ to 50℃.
l Maximum voltage between any output terminal and earth: 30Vpk
Maximum output current: Approximately 25mA.
General Specifications for Pressure
| Function | Reference | Range | Resolution | Accuracy | Remark | 
| PRESSURE | Determined by pressure module | _____ | Determined by pressure module | Determined by pressure module | For more detail, refer the pressure module about APM. | 










|   | 
 2 Wire RTD Multifunction Process Calibrator Thermocouple Calibration Equipment
                                                                                    
                        
                        
                        
                                                            2 Wire RTD Multifunction Process Calibrator Thermocouple Calibration Equipment
                                                    
                        
                     100MV Digital Signal Generator Analog Transmitter Source Simulator
                                                                                    
                        
                        
                        
                                                            100MV Digital Signal Generator Analog Transmitter Source Simulator
                                                    
                        
                     VICTOR 71B Rtd Temperature Calibrator Portable Signal Process Calibrator
                                                                                    
                        
                        
                        
                                                            VICTOR 71B Rtd Temperature Calibrator Portable Signal Process Calibrator
                                                    
                        
                     VICTOR 06 V/mA calibrator measure DCV DCA simulating output DC voltage, DC current
                                                                                    
                        
                        
                        
                                                            VICTOR 06 V/mA calibrator measure DCV DCA simulating output DC voltage, DC current
                                                    
                        
                     VICTOR 07 Temperature Calibrator Multi-function process calibrator thermocouple calibrator
                                                                                    
                        
                        
                        
                                                            VICTOR 07 Temperature Calibrator Multi-function process calibrator thermocouple calibrator
                                                    
                        
                     VICTOR 01S Temperature Signal Generator Temperature Source process calibrator multimeter
                                                                                    
                        
                        
                        
                                                            VICTOR 01S Temperature Signal Generator Temperature Source process calibrator multimeter
                                                    
                        
                     RTD Calibrator Thermocouple Multifunction Process Calibrator Temperature Calibrator Tc and RTD calibrator
                                                                                    
                        
                        
                        
                                                            RTD Calibrator Thermocouple Multifunction Process Calibrator Temperature Calibrator Tc and RTD calibrator
                                                    
                        
                     VICTOR 04S Voltage/mA Source calibrator tester Temperature calibrator simulator source transmitter calibrrator
                                                                                    
                        
                        
                        
                                                            VICTOR 04S Voltage/mA Source calibrator tester Temperature calibrator simulator source transmitter calibrrator
                                                    
                        
                     High Precision Voltage Current Loop Calibrator Handheld Auto Signal Generator current loop calibrator
                                                                                    
                        
                        
                        
                                                            High Precision Voltage Current Loop Calibrator Handheld Auto Signal Generator current loop calibrator
                                                    
                        
                     2 Wire RTD Multifunction Process Calibrator Thermocouple Calibration Equipment
                                                                                    
                        
                        
                        
                                                            2 Wire RTD Multifunction Process Calibrator Thermocouple Calibration Equipment