ASTM D2843 Burning Smoke Density Tester for Building Materials
1. Scope of application
Touch-screen computer dual control smoke density tester for
building materials was developed according to the technical
conditions stipulated in GB/ T8627-2007 "test methods for smoke
density of burning or decomposition of building materials", which
is applicable to the measurement of static smoke production from
burning of building materials, products and other materials.
2. Product features
1. Dual control mode, can control the operation on the touch
screen, can also be controlled on the computer, the operation mode
can be arbitrarily switched!
2. A device can operate several computers at the same time, several
computers can be online at the same time, and LAN sharing can be
realized!
3. The main and auxiliary burners can rotate automatically and
locate accurately.
4. Independently developed the control program, which can meet all
kinds of operations, records, real-time curves and results
calculation in the test.
3. Relevant technical parameters
1. For the maximum smoke density (MSD) and smoke density grade
(SDR) of the specimen: 0-100% continuously measurable and
automatically calculated;
2. Calibration error with standard filter shall not be more than
3%;Each device is equipped with three standard filters, which are
representative of the data of light source calibration
3. Working pressure of Bunsen burner (210 + 5) KPa;
4. The Bunsen burner applied flame to the sample for 4min;
5. Burning lamp: in the Bunsen burner and a length of 260 mm, the
nozzle diameter of 0.13 mm, with smoke box into a 45 ° Angle;
6. Photoelectric system: the light source is a bulb with 15W power
and 6V working voltage;
7. Exhaust air system: this machine is equipped with powerful
exhaust fan, which can discharge exhaust gas out of the outdoor
after the test;
8. Smoke density measurement range: 0~100%;
9. Smoke density measurement accuracy: ±3%;
10. Receiver: silicon photocell, light transmittance 0% is no
light, light transmittance 100% is no shade completely through;
11. Working pressure of main burner: 276KPa (adjustable);
12. Automatic timing, automatic ignition, automatic smoke
extraction;Optical flux can be divided into stages for linear
correction test data more accurate;
13. Touch the screen:
| A. Size | 5 "effective display size 11cm long and 6.28cm wide; |
| B. Resolution | 800*480 |
| C. Communication interface | RS232, 3.3v CMOS or TTL, serial port mode |
| D. Storage capacity | 1G |
| E. Pure hardware FPGA drive display, "zero" startup time, power can run | |
| F. M3+FPGA architecture is adopted. M3 is responsible for instruction analysis, and FPGA focuses on TFT display | |
| G. The main controller adopts a low-energy processor and automatically enters the energy-saving mode | |
14. Gas source: 95% propane gas, or gas of the same purity
(customer provided);
15. Length * width * height 740 *500*900 (mm)
4. Working conditions
1. Ambient temperature: 0 ºC and 40 ºC;
2. Relative humidity: less than 85%
3. Power supply voltage and power: 220V + / - 10%, 50HZ, 100W;
4. Gas pressure: 0-0.3mpa (adjustable);
5. Environment and test requirements: avoid direct irradiation or
reflection of strong light on the instrument during operation;After
the test for 90min, the gas source should be turned off to cool the
instrument for 15min.
6. Ambient air flow: there is no forced air flow phenomenon when
working;
7. The instrument should be placed in the fume hood for testing;
5. Instrument structure
Divided into smoke box and control two parts;
Smoke box: on the left and right sides of the smoke box panel,
there are power switch, safety sign switch (back light switch), gas
regulator, in addition to the control exhaust fan switch (fan
switch).
Design standard
GB/ t8627-2007 smoke density test method for combustion or
decomposition of building materials
Standard: GB/T8627 ASTM D2843
|