| 1.Channel performance: | Type: terminal Darlington transistor output; load: maximum current 50 mA @ 24 VDC, starting voltage not greater than 19.2V, resistance Resistance from 700 to 32002 | 
| 2.Communication performance: | Agreement: RS-485, MODBUS RTU extension protocol; Rate: 691.2kbps | 
| 3.Power supply: | System: 1 W @ 24 Vdc + 10%; site: 5 W @ 24 Vdc + 10% | 
| Company Info. | 
| Chongqing Chuanyi Automation Limited | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
The DO module is a 16-channel 24VDC digital output module of the PAS300 system, which can be used with a universal base or a special relay base. The module unit consists of an I / 0 module, a module base, power bus and communication bus. The panel provides a rich state indicator light, used to display the module power supply, communication, channel working status, to enhance the efficiency of the work.


1. Active contacts require external auxiliary power supply and are
selected by jumper. Does not directly drive the field equipment and
needs to be configured with the relay module
2. Each channel can conduct fault output configuration separately,
which can maintain the previous cycle data or output preset safety
value in case of communication interruption or channel output
failure.
3. Communication protocol based on Modbus, with online diagnosis,
online replacement module, fast communication speed, and online
maintenance and update program.
4. The field power supply and the system power supply are used to
separate the power supply, and the field interference will not
affect the digital circuit and communication.
|   | 
 PAS-300 Automation Control System Distributed Control System Integrated Management
                                                                                    
                        
                        
                        
                                                            PAS-300 Automation Control System Distributed Control System Integrated Management
                                                    
                        
                     WS2100 Series Of Water Vapor Centralized Sampling And Analysis Device
                                                                                    
                        
                        
                        
                                                            WS2100 Series Of Water Vapor Centralized Sampling And Analysis Device
                                                    
                        
                     WS3000 Sewage Continuous Monitoring System
                                                                                        
                                                        
                        
                        
                        
                                                            WS3000 Sewage Continuous Monitoring System
                                                    
                        
                     70X3 Series Explosion-Proof Water Analyzer PH ORP Conductivity / Resistivity Measurement With 24V DC Source
                                                                                    
                        
                        
                        
                                                            70X3 Series Explosion-Proof Water Analyzer PH ORP Conductivity / Resistivity Measurement With 24V DC Source
                                                    
                        
                     AO Module (Display the module power supply and the field equipment communication
                                                                                    
                        
                        
                        
                                                            AO Module (Display the module power supply and the field equipment communication
                                                    
                        
                     70X6 Series Water Quality Analyzer(The parameters including pH / 0RP, conductivity / resistivity, dissolved oxygen,
                                                                                    
                        
                        
                        
                                                            70X6 Series Water Quality Analyzer(The parameters including pH / 0RP, conductivity / resistivity, dissolved oxygen,
                                                    
                        
                     7091 Series Water Quality Analyzer (Sodium ion / silicate / phosphate / hydrazine analysis in water
                                                                                    
                        
                        
                        
                                                            7091 Series Water Quality Analyzer (Sodium ion / silicate / phosphate / hydrazine analysis in water
                                                    
                        
                     TC2000Multi-Parameter Intelligent Controller (Support the independent access of 19 kinds of sensors、HART
                                                                                    
                        
                        
                        
                                                            TC2000Multi-Parameter Intelligent Controller (Support the independent access of 19 kinds of sensors、HART
                                                    
                        
                     Fluorescence Dissolved Oxygen Measuring Instrument  (Monitoring of dissolved oxygen in sewage treatment plant;
                                                                                    
                        
                        
                        
                                                            Fluorescence Dissolved Oxygen Measuring Instrument  (Monitoring of dissolved oxygen in sewage treatment plant;