2 Zone Conventional Fire Alarm Panel Wall Mounted For Fire Fighting System

Categories Conventional Fire Alarm System
Brand Name: XHA
Model Number: XHA1002
Certification: CE
Place of Origin: China
MOQ: 4PCS
Payment Terms: T/T, Western Union
Delivery Time: 3 Working days
Packaging Details: 465*405*285mm
Connected: 2/4/8/16 Zone
Installation: Wall Mounted
Communication: RS485
Trademark: XHA1002
Origin: China
HS Code: 8531100000
Supply Ability: 1000/Month
Type: Conventional Fire Alarm Controller
Types of Smoke Detectors: Photoelectric Smoke Style
Customization: Available | Customized Request
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

2 Zone Conventional Fire Alarm Panel Wall Mounted For Fire Fighting System

Conventional Fire Alarm Panel 2 Zone For Fire Fighting System


Conventional 4/8/16 Zone Fire Alarm Control Panel for Automatic Fire Fighting System

Introduction

The fire alarm control panels (2 Zone,4 Zones, 8 Zones, and 16 Zones) provide all of the sophisticated features required of a
leading edge conventional fire alarm system along with the simple operation and efficient installation methods
demanded by both installers and building users.
The panel can be flush or surface mounted and the generously sized metal back box allows ample space for rear or top
cable entries.
A comprehensive range of auxiliary devices is available to operate with the fire control panels including optical,
ionization, photoelectric, photoelectric-thermal and heat detectors.
Each of the system components has been specifically designed to operate as part of the system. This provides
assurance that the control panel, smoke detectors, interface devices and the ancillary components are all fully
compatible with one another and that the full range of system functionality is supported by each device.
This series of panels are basically the same in application and operation, their differences are shown in Table 1. PANEL
will be described as the example in the following sections.



Product Features

4,8,16 Class B Initiating Device Circuits (lDCs).
. All zones accept conventional detectors and any normally open contact device.
. Four Class B Notification Appliance Circuits (NACs).
. One Form-A Alarm Relay.
. One Form-A Fault Relay.
. One Form-A Supervisory Relay
. 3.0 amps ofsystem power.
. Max 30 conventional detectors in one zone.
. Auto/Manual mode setting enable.
. Each Zone can be disabled.
. Sound output can be disabled.
. Manual active sound output enabled.
. Able to report short and broken circuit
of detection zones.
. Designed with standby batteries and space provision for 1 sealed lead- acid batteries
Evacuate,Testing and disable functions.
. Remote reset and silence alarm functions
. Can conneet max 32 repeater panels by RS485 communication port
. Dimensions :14.57"(37 cm) long X 17.32"(44 cm) high X 3.94"(10cm)
. Weight: 6.6kg (without battery)


Specification
Primary AC120VAC 50/60 Hz Power supply rating
240VAC 50/60 Hz
Power supply rating2 Amps @ 24VDC
Maximum Battery Charging Current0.98 Amps @ 26VDC
Initiating Device Circuits 2 ZonesAlarm Zone 2
Normal Initiating Operating Voltage23VDC, Maximum 26VDC, regulated
Normal Quiescent Current (normal status)<50mA
Alarm Current (not include the others)<150 mA
Short Circuit Initiating Current (per zone)35mA Maximum
Maximum Initiating Resistance (per zone)10 ohms
Initiating End-of-Line Resistor4K7 ohms, 1/2W 5%
Standby Detector Current (per zone)4mA maximum
Maximum Detector Count (per zone)30 detectors
Initiating Cabling Type18AWG Twisted Shielded pair (14 – 18 AWG)
Detector Base Impedance430 ohms
Notification Appliance Circuits1 NACs, Special Application
Maximum NAC Current Rating1 Amp maximum per circuit
NAC Operating Voltage26VDC Nominal, 30VDC Maximum
NAC End-of-line Resistor1N4007 Diode
FAULT Relay rating2A & 30VAC, resistive
Alarm( Auxiliary ) Relay rating2A & 30VAC, resistive
Master alarm panelDigital & LED display
Slave alarm panelLED display only


Product range

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
Standalone smoke detectors and combustable gas detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system




Service


1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.