Mindray DC-8 The Blood Flow Button Fails And The Machine Reports A Keyboard Card Key Alarm
Mindray DC-8 The Blood Flow Button Fails And The Machine Reports A Keyboard Card Key Alarm
Repair results: After replacing the control panel, the machine returned to normal use.
Common Probe failure
1. Lens: Acoustic lens damage or bulge
2. Cable: the cable is damaged and the shell is cracked
3. Image attenuation: aging attenuation
4. Shadow: dark vertical line
5. Not recognized: probe not recognized
6. Interference: probe interference
| 2D Probe Repair | |
| Service Brand | GE,,Siemens,Hitachi Aloka,Toshiba,Biosound Biosound,Sumsang Medison | 
| Service Type | Linear,Convex,Phased,Sector,Endocavity | 
| Repair Range | Membrane/lens replacement,Strain relief replacement,Electronic connector repair,Crystal/Array replacement,Plastic housing repair,Connecting cable repair | 
Other Minadary compatible probes we can repair:
| Brand | Model | Compatible System | 
| Mindray | 35C50HA | DP-9900Plus | 
| Mindray | 75L38HA | DP-9900Plus | 
| Mindray | 65EC10HA | DP-9900Plus | 
| Mindray | 35C50EA | DP-8800Plus,DP-6600,DP-6600Vet,DP-50,DP-6900,N2 | 
| Mindray | 35C50EB | DP-7700,DP-3300,DP-3300Vet,DP-2200,DP-1100 Plus,DP-10,DP-20 | 
| Mindray | 75L38EA | DP-8800Plus,DP-6600,DP-6600Vet | 
| Mindray | 75L38EB | DP-7700,DP-3300,DP-3300Vet,DP-2200,DP-1100 Plus,DP-10,DP-20 | 
| Mindray | 65EC10EA | DP-8800Plus,DP-6600,DP-6600Vet,DP-50 | 
| Mindray | 65EC10EB | DP-7700,DP-3300,DP-3300Vet,DP-2200,DP-1100 Plus,DP-10,DP-20,DP-4800 | 
| Mindray | 65C15EAV | DP-8800Plus,DP-6600,DP-6600Vet,DP-50,DP-10 | 
| Mindray | 50L60EA | DP-6600Vet, DP-5 | 
| Mindray | 35C20EA | DP-8800Plus,DP-6600,DP-6600Vet,DP-50,DP-6900 | 
| Mindray | 3C5/A | DC-6,DC-3 | 
| Mindray | C5-2 | DC-7 | 
| Mindray | V10-4 | DC-N3 DC-N6 DC-T6 | 
| Mindray | L11-4 | DC-7 | 
| Mindray | 3C5S | M5,M7 | 
| Mindray | 3C5P | Z6 | 
| Mindray | L12-3E | DC-8 | 
| Mindray | V11-3E | DC-8 | 
| Mindray | C5-2E | DC-8 | 
Picture

FAQ
Q: Is there any guarantee for the goods?
A: Fully-tested and safe packing before shipping, less than 3%
warranty return claims of previous orders.
Q: Will you provide warranty?
A: Items are sold with NO WARRANTY, unless it is stated otherwise in the body of the proforma invoice/purchase order. Mostly 90 days for new original, 30/60 days for used.
Q: If faults occurred after warranty date, can I contact you?
A: Sure, feel free to contact even years later. We'll look into the
faults and try to find out some solutions/suggestions for you
reference.
Q: How about the payment terms?
A: All orders are 100% prepaid before delivery. We accept wire
transferring / Western Union from bank, and cash. (US dollars,
Euro, or CNY)
Q: How about delivery?
A: We ship worldwide. DHL/EMS/FedEx Express will be arranged within 1-5 working days after payment confirmed unless otherwise specified. We Seller are responsible for export Customs clearance in our end, and buyers for import Customs clearance in their end.
|   | 
 Preirus Troubleshoot Ultrasound Machine Repair Hitachi Aloka
                                                                                        
                                                        
                        
                        
                        
                                                            Preirus Troubleshoot Ultrasound Machine Repair Hitachi Aloka
                                                    
                        
                     S2000 Color Doppler Medical Machine Repair For Startup Failure
                                                                                        
                                                        
                        
                        
                        
                                                            S2000 Color Doppler Medical Machine Repair For Startup Failure
                                                    
                        
                     GE Clinic Ultrasound Machine Repair
                                                                                        
                                                        
                        
                        
                        
                                                            GE Clinic Ultrasound Machine Repair
                                                    
                        
                     EPIQ 7 Ultrasound Machine Repair
                                                                                        
                                                        
                        
                        
                        
                                                             EPIQ 7 Ultrasound Machine Repair
                                                    
                        
                     IE33 Ultrasonic Diagnostic Instrument Common Fault
                                                                                        
                                                        
                        
                        
                        
                                                             IE33 Ultrasonic Diagnostic Instrument Common Fault
                                                    
                        
                     GE Vivid7 Ultrasound Machine Maintenance Run Failure
                                                                                        
                                                        
                        
                        
                        
                                                            GE Vivid7 Ultrasound Machine Maintenance Run Failure
                                                    
                        
                     SSA 580A Toshiba System Repair , clinic RX board maintenance
                                                                                        
                                                        
                        
                        
                        
                                                            SSA 580A Toshiba System Repair , clinic RX board maintenance
                                                    
                        
                     Clinic Acuson Ultrasound Machine Repair For Display Problem
                                                                                        
                                                        
                        
                        
                        
                                                            Clinic Acuson Ultrasound Machine Repair For Display Problem
                                                    
                        
                     IU22 Ultrasonic Machine Repair No Display Failure
                                                                                        
                                                        
                        
                        
                        
                                                             IU22 Ultrasonic Machine Repair No Display Failure
                                                    
                        
                     KTI301394-2 Ultrasound Machine Repair GE Voluson E6 Voluson E8 RSR
                                                                                        
                                                        
                        
                        
                        
                                                            KTI301394-2 Ultrasound Machine Repair GE Voluson E6 Voluson E8 RSR