Sign In | Join Free | My carsrow.com
carsrow.com
Products
Search by Category
Home > Hunting >

Illumination Locating 3NH NH300 Color Difference Meter 8mm Aperture

Categories Color Difference Meter
Brand Name: 3nh
Model Number: NH300
Certification: CE,RoHs,ISO,etc.
Place of Origin: Shenzhen China
MOQ: 1pc
Price: discuss
Payment Terms: T/T,Paypal, etc
Supply Ability: 1000pcs/month
Delivery Time: 2 work days
Packaging Details: Standard export package
Model: NH300
Locating: Illumination Locating
Calibration: Manual
Accuracy: delta e <0.07
Light Source: D65
Color Space: Lab XYZ
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Illumination Locating 3NH NH300 Color Difference Meter 8mm Aperture

3NH NH300 Portable Colorimeter with 8mm aperture

Company info. :

Shenzhen 3nh Technology Co., Ltd. is a high-tech enterprise. We research, develop, produce and market photoelectric detection products in photoelectric detection technology field and color management field.


Our Certificates:
ISO9001:2008; CE; FCC; ROHS; TUV.


The parameters of test results are integrating with international standards. Our products are exported around the world. We can provide customization service which has been well received by customers.

Brief Introduction:

1.Aperture:8mm

2.Accuracy:0.07

3.Illuminant:D65

4.CQCS3 software


NH300 colorimeter, easy to use and cost-effective, widely used in R&D, quality control and production management department, can measure color difference accurately and quickly. NH300 colorimeter is equipment with quality control management software which can connect the computer to realize more fuction.

Application :

It's used to compare color difference in plastic, electronic, painting, coating, ink, texile, garment, printing, dyeing, food, medical, cosmetic industries and institutes, schools and laboratoris.


Features:

1. Leading Humanity Design and Convenient Operatio


2. Stable Measurement Performance


3. Convenient and Fast Locating


4. PC Software—Realize More Function Expansion


5. Advanced Power Management Design


Specification :

Illuminating geometry: 8/d (8°illumination angle/diffuse viewing)

Measuring Aperture: 8mm

Storage: 100pcs standards 20000pcs samples

Repeatability: Standard deviation within ΔE*ab 0.07;Average of 30 measurements of standard white plate

Errors Between Each Equipment: ≤0.40ΔE*ab

Light source: D65

Lamp Life: 5 years, more than 1.6 million measurements

Data Interface: USB

Temperature Range: -10°Cto 40 °C

Humidity Range: less than 85% relative humidity, no condensation

Weight: 500g

Dimensions: 205 x 70 x 100 mm


Product Image :
Plastic Color Compare NH300 Colorimeter
Plastic Color Compare NH300 Colorimeter
Plastic Color Compare NH300 ColorimeterPlastic Color Compare NH300 Colorimeter
FAQ:

1. When I received NH310/NH300 colorimeter and perform measurement, why the measured data is abnormal?


After receiving NH310/NH300, you have to perform white and black calibration manually when first starting.


2. In which condition, manual white and black calibration and auto calibration are required for NH310?


a. It’s needed to perform manual calibration for NH310 when first starting.
b. In the subsequent starting, NH310 will perform auto calibration at startup. No need to perform manual calibration.
c. Suggestion: it’s best to perform manual calibration once a week or when NH310 measured data is not accurate.

4. How to replace NH310 measuring aperture?


There are three measuring apertures for NH310: Φ8mm (standard accessory), Φ4mm (standard accessory), extended Φ8mm (optional accessory)
a. Turning on
b. Removing measuring aperture, install the needed measuring aperture.


c. Select “Settings-Aperture Setting” in main menu to select corresponding measuring aperture.


d. After selecting aperture, the instrument will display “White and Black Calibration” interface. White and black calibration must be performed.
e. Replace completed.

3. In which condition, manual white and black calibration for NH300 is required?


a. It’s needed to perform manual calibration for NH300 when first starting.


b. In the subsequent starting, no need to perform manual calibration.


c. Suggestion: it’s best to perform manual calibration once a week or when NH300 measured data is not accurate.

5. CQCS3 (Color Quality Control System) Installation


a. Before installation, please Copy CQCS3 folder to your computer and don’t remove any files in CQCS3 folder.


b. Double-click the setup.exe to install CQCS3 software.


c. Then double-click Install.bat under the CQCS3USB_Driver file to install the driver.
d. Detailed installation information please read the "Installing Software" under CQCS3 User manual.doc.

Customer confirmation :
Plastic Color Compare NH300 Colorimeter
Contact Info.
photobank (1)
Waiting for you inquiry. Any more questions you can contact me directly, I will reply asap.

Related Knowledge about Spectrophotometer:


Color Space

CIE LAB
-L(Lightness)-0 is black,100 is white
-a(Red-Green)-positive values are red; negative values are green and 0 is neutral
-b(Blue-Yellow)-positive values are yellow;negative values are blue abd 0 is neutral

CIE LCH
L: Lightness,value is the same in each scale C:Chroma H:Hue Angle

dE Total Color difference
Delta-E is a measurement used to indicate how much a color deviates from an accepted standards.The higher the dE, the more inaccurate the color.

Quality Illumination Locating 3NH NH300 Color Difference Meter 8mm Aperture for sale
Send your message to this supplier
 
*From:
*To: Shenzhen ThreeNH Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0