| Sign In | Join Free | My carsrow.com | 
 | 
| Categories | Electromagnetic Flow Meter | 
|---|---|
| Brand Name: | NUOYINGJIAYE | 
| Model Number: | NYLD-CR | 
| Certification: | CE | 
| Place of Origin: | Xi'an, Shaanxi,China | 
| MOQ: | 1 | 
| Price: | Please Contact Me | 
| Payment Terms: | T/T | 
| Delivery Time: | 7-15 working days | 
| Packaging Details: | Carton, 60cm×30cm×30cm | 
| Typical application: | Liquid flow measurement | 
| straight pipe: | Front 5DN, Rear 3DN | 
| Medium temperature: | -20℃~/+130℃ | 
| Ambient temperature: | -20℃~/+60℃ | 
| Environment humidity: | 5~100%RH (relative humidity) | 
| Power supply: | AC220V 50Hz /DC24V/3.6V | 
| Connection method: | Thread,flange (optional) | 
| Electrode material: | 316L Stainless steel | 
| Company Info. | 
| Xi'an Dehou Electronic Technology Co., Ltd. | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
Upper Alarm Empty Alarm Insertion Electromagnetic Flow Meter
Insertion Electromagnetic Flow Meter Discription
NYLD-CR insertion electromagnetic flow meter is a new type of flow meter developed on the basis of pipeline electromagnetic flow meter. On the basis of retaining the advantages of pipeline electromagnetic flow meter, it is installed on pipeline for pipeline electromagnetic flow meter. Difficulty, high cost and other defects, according to the principle of NIKURADS, the volume flow of the fluid is obtained by measuring the average flow rate of the fluid by electromagnetic method. Especially after adopting the technology of press-opening and press-installation, the plug-in electromagnetic flow meter can be installed without stopping the water, and it can also be installed on cast iron pipes and cement pipes. The successful development of the plug-in electromagnetic flow meter provides a new method for the detection of fluid flow.
Insertion Electromagnetic Flow Meter Design Feature
◎In the pipeline flow detection, the installation is simple, the flow can be continuous, and the holes can be opened under pressure on site, which has absolute installation advantages and price advantages.
◎It is suitable for flow detection of liquids with conductivity above 20µs/cm, such as water, sewage, acid, strong alkali, etc. The change of conductivity does not affect the performance change. Strongly adapt to complex changes in fluid, especially suitable for flow measurement of water supply and drainage pipelines
◎The mechanical movable parts of the flow meter, the converter adopts an optimized design, the structure is compact, and it is easy to install. The converter and the sensor are interchangeable, and the detection range of the flow measurement can be freely changed (0.5m/s~10m/s).
◎It is only related to the insertion depth, so it has wide versatility and strong interchangeability. One model can be applied to the fluid measurement requirements of various sizes of pipelines. Range automatic switching function. When the flow meter changes in the flow range, the range can be automatically switched to ensure accurate measurement within the full range.
| Typical application | Liquid flow measurement | 
| Measuring range | Custom design | 
| Pipe diameter | 300-3000mm | 
| Velocity range | 0.1~10m/s | 
| Accuracy | 0. 5 ~ 10 m / s: ±1.5% FS;0.1 ~ 0.5 m / s; ±2.0% FS | 
| Conductivity | >50µs/cm | 
| straight pipe | Front 5DN, Rear 3DN | 
| Medium temperature | -20℃~/+130℃ | 
| Ambient temperature | -20℃~/+60℃ | 
| Environment humidity | 5~100%RH (relative humidity) | 
|   | 
 IP68 Intelligent Electromagnetic Flow Meter 0.1-10m/S 4-20mA
                                                                                    
                        
                        
                        
                                                            IP68 Intelligent Electromagnetic Flow Meter 0.1-10m/S 4-20mA
                                                    
                        
                     NYLD Tubular Electromagnetic Flow Meter High Reliability Modbus Protocol
                                                                                    
                        
                        
                        
                                                            NYLD Tubular Electromagnetic Flow Meter High Reliability Modbus Protocol
                                                    
                        
                     1.6MPa 2.5Mpa Mag Water Flow Meter Nominal Diameter Electromagnetic
                                                                                    
                        
                        
                        
                                                            1.6MPa 2.5Mpa Mag Water Flow Meter Nominal Diameter Electromagnetic
                                                    
                        
                     Flange Type Electromagnetic Flow Meter 1Mpa Forward Reverse
                                                                                    
                        
                        
                        
                                                            Flange Type Electromagnetic Flow Meter 1Mpa Forward Reverse
                                                    
                        
                     IP68 Electromagnetic Water Meter DN40 DN300 High Measurement Accuracy
                                                                                    
                        
                        
                        
                                                            IP68 Electromagnetic Water Meter DN40 DN300 High Measurement Accuracy
                                                    
                        
                     NYLD Pipeline Type Electromagnetic Flow Meter For Liquid Measurement
                                                                                    
                        
                        
                        
                                                            NYLD Pipeline Type Electromagnetic Flow Meter For Liquid Measurement
                                                    
                        
                     316SS Insertion Electromagnetic Flowmeter ABS PTFE Lining IP67
                                                                                    
                        
                        
                        
                                                            316SS Insertion Electromagnetic Flowmeter ABS PTFE Lining IP67
                                                    
                        
                     Soy Sauce Electromagnetic Flow Meter RS485 316L Electromagnetic Flow Switch
                                                                                    
                        
                        
                        
                                                            Soy Sauce Electromagnetic Flow Meter RS485 316L Electromagnetic Flow Switch
                                                    
                        
                     Liquid Insertion Type Electromagnetic Flowmeter NYLD - CR Limit Alarm
                                                                                    
                        
                        
                        
                                                            Liquid Insertion Type Electromagnetic Flowmeter NYLD - CR Limit Alarm
                                                    
                        
                     1Mpa 2.5Mpa 4Mpa Electromagnetic Flow Transmitter 15mm To 800mm
                                                                                    
                        
                        
                        
                                                            1Mpa 2.5Mpa 4Mpa Electromagnetic Flow Transmitter 15mm To 800mm