| Sign In | Join Free | My carsrow.com | 
 | 
| Categories | Optical Return Loss Meter | 
|---|---|
| Brand Name: | YOUCii | 
| Model Number: | U8784 | 
| Place of Origin: | CHINA | 
| MOQ: | 1pcs | 
| Price: | negotiate a price | 
| Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram | 
| Supply Ability: | 20 pcs+per month | 
| Delivery Time: | 20 work days | 
| Packaging Details: | Carton | 
| Certification: | CU,IOS | 
| Product name: | Optical Return Loss Meter | 
| Working wavelength range: | 1529nm To 1569nm | 
| Optical channels: | 16 | 
| Measuring wavelength range: | 40 | 
| Measurement resolution: | 0.1pm | 
| Model: | U8784 | 
| Company Info. | 
| Guangzhou UC Instruments., Co. Ltd. | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
U8784 Optical performance monitoring module
| Parameter | Unit | Indicator | 
| Working wavelength range | nm | 1529~1569 | 
| Number of optical channels | 16 | |
| Measuring wavelength range | nm | 40 | 
| Minimum detectable wavelength separation | nm | 0.5 | 
| Measurement resolution | pm | 0.1 | 
| Wavelength repeatability | pm | £5 | 
| Sweep frequency | Hz | 100 | 
| Optical interface | FC/APC | |
| Communication Interface | RJ45,RS232 | |
| Working temperature | ℃ | 0~50 | 
| Storage temperature | ℃ | -10~70 | 
| Operating voltage | V | DC 12 | 
| Power consumption | W | £18 | 
| Weight | kg | <2 | 
| Dimensions | mm | 225´172´28 | 
U8784 is a 16-channel high-speed optical performance monitoring module with high integration and good stability. It is suitable for FBG sensor system to monitor physical parameters such as temperature, dynamic stress and vibration.
This module uses the patented PIC photonic integration technology with wavelengths ranging from 1529nm to 1569nm. The wavelength, spectrum and other data of the grating to be measured can be reported to the upper computer through the RJ45 network port.
FAQ
Q: Are your company a trading one or a factory?
A: We are a fcatory in Guangdong. Our company has a professional
foreign trade sales team and an experienced technical support team.
We are supplier for Light source, optical power meter, optical
attenuator, optical switch and BERT, DCA, CDR.
Q: What is the price term?
A: FOB ShenZhen
Q: What’s the warranty time?
A: 12 months after shipment date.
Q: How to place order?
A: Talk to service staff, confirm machine details, and then place
order.
|   | 
 UC8523  Insert Return Loss Meter 1310Nm 1550Nm Dual Wavelength
                                                                                    
                        
                        
                        
                                                            UC8523  Insert Return Loss Meter 1310Nm 1550Nm Dual Wavelength
                                                    
                        
                     1.0pm Laser Scanning Spectrometer With Output Power 13 DBm Easy To Operate
                                                                                    
                        
                        
                        
                                                            1.0pm Laser Scanning Spectrometer With Output Power 13 DBm Easy To Operate
                                                    
                        
                     Two Channels Laser Scanning Spectrometer ±5 Pm Typ 24 Hrs At Constant Temperature
                                                                                    
                        
                        
                        
                                                            Two Channels Laser Scanning Spectrometer ±5 Pm Typ 24 Hrs At Constant Temperature
                                                    
                        
                     1525nm Laser Scanning Spectrometer With 2 Probes Optical Communication Detection
                                                                                    
                        
                        
                        
                                                            1525nm Laser Scanning Spectrometer With 2 Probes Optical Communication Detection
                                                    
                        
                     RS232 Insert Return Loss Meter Optical Communication Testing Equipment
                                                                                    
                        
                        
                        
                                                            RS232 Insert Return Loss Meter Optical Communication Testing Equipment
                                                    
                        
                     SMO Fiber Optical Return Loss Meter By Light Source External With Probe
                                                                                    
                        
                        
                        
                                                            SMO Fiber Optical Return Loss Meter By Light Source External With Probe
                                                    
                        
                     60dB Optical Return Loss Meter 2/3/4/5 Multiwavelength Loss Recovery Instrument
                                                                                    
                        
                        
                        
                                                            60dB Optical Return Loss Meter 2/3/4/5 Multiwavelength Loss Recovery Instrument
                                                    
                        
                     10G Four Channel Multi Rate Error Meter 9.953/10.3125G BERT
                                                                                    
                        
                        
                        
                                                            10G Four Channel Multi Rate Error Meter 9.953/10.3125G BERT
                                                    
                        
                     The Wavelength Range Of O Band Laser Scanning Spectrometer Is 1260~1360nm
                                                                                    
                        
                        
                        
                                                            The Wavelength Range Of O Band Laser Scanning Spectrometer Is 1260~1360nm
                                                    
                        
                     Dual Wavelength Insertion Loss Instrument Single Light Source Outlet
                                                                                    
                        
                        
                        
                                                            Dual Wavelength Insertion Loss Instrument Single Light Source Outlet