| Sign In | Join Free | My carsrow.com | 
 | 
| Categories | Optical Oscilloscope | 
|---|---|
| Brand Name: | YOUCii | 
| Model Number: | U9710B | 
| Place of Origin: | CHINA | 
| MOQ: | 1pcs | 
| Price: | negotiate a price | 
| Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram | 
| Supply Ability: | 5 pcs+per month | 
| Delivery Time: | 20 work days | 
| Packaging Details: | Carton | 
| Certification: | CU,IOS | 
| Product name: | 10Gbps Clock Recovery Module | 
| Application: | Optical Network Equipment | 
| Model: | U9710B | 
| Wavelength range: | 800nm | 
| Data rate: | 10Gbps | 
| Custom: | available | 
| Company Info. | 
| Guangzhou UC Instruments., Co. Ltd. | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
U9710B Full Rate 10Gbps CDR
| No. | Specifications | Max. | Min. | Unit. | 
| 1 | Data rate range | 11.3 | 0.155 | Gbps | 
| 2 | Wavelength range | 1600 | 800 | nm | 
| 3 | Optical input range (determined by module sensitivity) | +3 | -15 | dBm | 
| 4 | Output recovered electrical clock range | 5.65 / 2.825 | 0.0775/0.03875 | GHz | 
| 5 | Output electrical clock amplitude | 600(typical value) | mVpp | |
| 6 | Clock rise time(OC-192)(20%~80%) | 33.1 | 22.2 | ps | 
| 7 | Clock fall time(OC-192)(80%~20%) | 33.7 | 23.9 | ps | 
| 8 | Output Jitter(10.3125Gbps) | 1 (typical value) | ps | |
| 9 | Clock frequency(10.3125Gbpsrate, divided by2/4) | 5.156 / 2.578 | 5.156 / 2.578 | GHz | 
| 10 | Internal Loss of Signal Detect (LOS) | 128 (overload) | 5 (sensitivity) | mV | 
| 11 | Power supply voltage (input voltage of external power supply) | 5.5 | 4 | V | 
| 12 | Operating temperature | 85 | -40 | ℃ | 
U9710 CDR (Clock Recovery Module ) is mainly used to provide clock
recovery signal in the test environment without triggering clock,
so as to use the sampling oscilloscope to test the optical eye
diagram of the device. The typical application is the testing of
optical network equipment or the BOB product in PON application.
Because the photometric device itself has no frequency division
clock output, it is necessary to recover the clock signal to
trigger the sampling oscilloscope when testing the optical eye
diagram.
U9710 CDR has a SFP optical port, which is suitable for SFP
encapsulated conventional SFP, SFP+, OLT SFP and other optical
modules. It only needs the receiving end of the optical module to
convert the optical signal to the electrical signal, and then
extract and output the clock of the electrical signal. Clock signal
is mainly used for the trigger signal of oscilloscope. This device
self-adapts to the rate and does not require software
configuration.
FAQ
Q: Are you a factory manufacturer?
A: Yes we are manufacturer with 13 years experience in this industry and supplied many good quality products.
Q: Where is your main market?
A: Asia, Europe, America, Middle-East, Africa and other countries and regions.
Q:What is your minimum order quantity (MOQ)?
A: As a standard policy, we accept MOQ of 1set, and mixed items available, it still needs to confirm with our sales according to different product lines.
Q: Can I customize the size and color of the case?
A: Yes. We can discuss it .
Q: Can I buy some samples first before main orders? Is the sample fee refundable?
A: Yes, sample fee and shipment fee should be paid in advance .
Q: How long is the Production Lead Time?
A: 5 days for stock products, different products have different delivery times, according to the actual situation.
|   | 
 Dual Channel Polarization Preserving Optical Attenuator  0~45DB
                                                                                    
                        
                        
                        
                                                            Dual Channel Polarization Preserving Optical Attenuator  0~45DB
                                                    
                        
                     USB Optical Oscilloscope Four Channel Multi Rate BERT Support 10Gbps 9.953/10.3125G
                                                                                    
                        
                        
                        
                                                            USB Optical Oscilloscope Four Channel Multi Rate BERT Support 10Gbps 9.953/10.3125G
                                                    
                        
                     Fast Speed Optical Oscilloscope 100G 400G BERT Bit - Error Tester Support 9.953-11.3G/25-28G
                                                                                    
                        
                        
                        
                                                            Fast Speed Optical Oscilloscope 100G 400G BERT Bit - Error Tester Support 9.953-11.3G/25-28G
                                                    
                        
                     10G Full Rate BERT Support 622M-15G An Electric One Mouthful Dual Channel
                                                                                    
                        
                        
                        
                                                            10G Full Rate BERT Support 622M-15G An Electric One Mouthful Dual Channel
                                                    
                        
                     100G/400G Bit Error Tester BERT 240V SMA Connector Type
                                                                                    
                        
                        
                        
                                                            100G/400G Bit Error Tester BERT 240V SMA Connector Type
                                                    
                        
                     10G Four Channel Bit Error Tester BERT Support 10Gbps Multiple Rates
                                                                                    
                        
                        
                        
                                                            10G Four Channel Bit Error Tester BERT Support 10Gbps Multiple Rates
                                                    
                        
                     Full Rate 10Gbps CDR Clock Recovery Module Adaptive Rate
                                                                                    
                        
                        
                        
                                                            Full Rate 10Gbps CDR Clock Recovery Module Adaptive Rate
                                                    
                        
                     10G Digital Communication Analyzer Low Speed DCA 1.2442/1.25G
                                                                                    
                        
                        
                        
                                                            10G Digital Communication Analyzer Low Speed DCA 1.2442/1.25G
                                                    
                        
                     10G Four Channel Bit Error Tester BERT Support 9.953Gbps 10.3125/10.519/10.702/11.096/11.317Gbps
                                                                                    
                        
                        
                        
                                                            10G Four Channel Bit Error Tester BERT Support 9.953Gbps 10.3125/10.519/10.702/11.096/11.317Gbps
                                                    
                        
                     10Gbps Full Rate 10Gbps CDR Clock Recovery Module 0.155~11.3G
                                                                                    
                        
                        
                        
                                                            10Gbps Full Rate 10Gbps CDR Clock Recovery Module 0.155~11.3G