| Brand Name: | RISING | 
| Model Number: | RSJFD-251 | 
| Certification: | ISO CE | 
| Place of Origin: | China | 
| MOQ: | 1 SET | 
| Payment Terms: | L/C, L/C, D/A, D/P, T/T, Western Union, MoneyGram | 
| Supply Ability: | 500 SET PER Month | 
| Packaging Details: | Wooden package | 
| Measuring channel: | 2 channels | 
| Detection sensitivity: | 0.1 pC | 
| Power supply: | AC220V±10%,50Hz | 
| Gain Dynamic Range: | 120 dB | 
| Synchronous Frequency: | 50,100,150,200Hz or any frequency | 
| Basic pulse Generator: | JFD-301 | 
| Company Info. | 
| Wuhan Rising Electric Co., Ltd. | 
| View Contact Details | 
| Product List | 
RSJFD-251 Partial Discharge Test Equipment
Partial Discharge Detection System with Computer
RSJFD system detection method is pulse current method which is currently most widely used in the world, the basic principle is following: when the test object generates one time partial discharge, there is the transient voltage change △U on both terminals of the test object ,then go to the detection impedance Zm via a coupling capacitance Ck, then there will be one pulse current I in the circuit. Sample the pulse voltage generated when this pulse current I passes the detection impedance Zm , amplified and displayed, finally, it can determine the actual loaded discharge, etc. of the partial discharge. The pulse current method mainly uses the lower frequency part of the partial discharge signal frequency spectrum, which can avoid wireless interference.
RSJFD system is a testing system in the form of pulse peak indication, it possesses functions such as computer program-controlled filtering, amplification, sampling, storage and display. It can test the actual loaded discharge q, discharge repetition rate n, average discharge current I, and quadratic rate D, it also can make different atlases: q-n, q-φ, q-φ-t, etc.
System Parameters of JFD-251 Partial Discharge Test System
| Measuring-channel | Channel 2 | 
| Detection sensitivity | 0.1 pC | 
| Programmable filter settings file | Low side 10, 20, 40 kHz High end 100,200,300 kHz | 
| Gain dynamic range | 120 dB | 
| Sampling rate | Every channel 0.1μs/dot | 
| Sample size | 8bit±1/2 LSB | 
| Synchronous frequency | 50,100,150,200Hz or any frequency | 
| Basic pulse generator | JFD-301 | 
| Basic pulse voltage | 0.2V,0.5V, 1V,2.0V,5V,10V Adjustable | 
| Standard capacity | 50pF,200pF Adjustable | 
| Calibration pulse voltage rise time | <60ns | 
| Calibration pulse voltage fall time | >100μs | 
| Work power | AC220V±10%,50Hz | 
|   | 
 RSJFD-IV Partial Discharge Test Equipment , Partial Discharge Detection System
                                                                                    
                        
                        
                        
                                                            RSJFD-IV Partial Discharge Test Equipment , Partial Discharge Detection System
                                                    
                        
                     Digital Partial Discharge Itinerant Machine -20℃~45℃ Work Temperature
                                                                                    
                        
                        
                        
                                                            Digital Partial Discharge Itinerant Machine -20℃~45℃ Work Temperature
                                                    
                        
                     HVJF-C Ultrasonic Partial Discharge Tester 6pF~250µF Capacitance Rang
                                                                                    
                        
                        
                        
                                                            HVJF-C Ultrasonic Partial Discharge Tester 6pF~250µF Capacitance Rang
                                                    
                        
                     Partial Discharge Test System RSJFD-251 120 dB Gain Dynamic Range
                                                                                    
                        
                        
                        
                                                            Partial Discharge Test System RSJFD-251 120 dB Gain Dynamic Range
                                                    
                        
                     RSPD-2C  Partial Discharge Test Equipment Comprehensive Analyzer
                                                                                    
                        
                        
                        
                                                            RSPD-2C  Partial Discharge Test Equipment Comprehensive Analyzer
                                                    
                        
                     Handheld Partial Discharge Detector High Voltage Equipment 0.85kg Weight
                                                                                    
                        
                        
                        
                                                            Handheld Partial Discharge Detector High Voltage Equipment 0.85kg Weight
                                                    
                        
                     RSJFS-V Partial Discharge Test Equipment -20~80dB Measuring Range
                                                                                    
                        
                        
                        
                                                            RSJFS-V Partial Discharge Test Equipment -20~80dB Measuring Range
                                                    
                        
                     High Frequency Partial Discharge Patrol Instrument 16.8v Lithium Battery
                                                                                    
                        
                        
                        
                                                            High Frequency Partial Discharge Patrol Instrument 16.8v Lithium Battery
                                                    
                        
                     High Frequency Partial Discharge Test Equipment 100K-50MHz Detection Bandwidth
                                                                                    
                        
                        
                        
                                                            High Frequency Partial Discharge Test Equipment 100K-50MHz Detection Bandwidth
                                                    
                        
                     Partial Discharge Test System Dynamic Range
                                                                                    
                        
                        
                        
                                                            Partial Discharge Test System Dynamic Range