| Sign In | Join Free | My carsrow.com | 
 | 
| Categories | Conductivity Analyzer | 
|---|---|
| Brand Name: | Daruifuno | 
| Model Number: | AEC2-H3A | 
| Certification: | CE | 
| Place of Origin: | China | 
| MOQ: | Negotiable | 
| Price: | Negotiable | 
| Product Name: | TDS Conductivity Meter | 
| Product Model: | AEC2-H3A | 
| Conductivity Resolution: | 0.001µS /cm | 
| Conductivity Range: | 0.00~200.00 mS/cm | 
| Operating Environment: | 0~60℃ | 
| Communication Method: | RS485 | 
| Shell Material: | reinforced ABS | 
| Protection Grade: | IP66 | 
| Dimension: | 144*144*120 mm | 
| Power Supply: | 100~240V AC | 
| Power Consumption: | 5W | 
| Installation Method: | Wall, pipe clamp, panel | 
| Company Info. | 
| Suzhou Delfino Environmental Technology Co., Ltd. | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
TDS Conductivity Meter RS485 TDS EC Analyzer With LCD Screen For Sewage Plants
Introduction
There are various dissolved salts in water, and exists in the form of ions. When a pair of electrodes are inserted in the water, after being energized, the charged ions will move in a certain direction under the action of the electric field. The anions in the water move to the anode to make the aqueous solution conduct electricity. The strength of the water's conductivity is called conductivity.
DRFN’s AEC2-H3A TDS conductivity meter can be connected to
different conductivity sensors with different cell constants to
achieve different measurement ranges. The conductivity measurement
range is from 0.00~200.00mS/cm.
Advantages Of The TDS Conductivity Meter

Applications Of The TDS Conductivity Meter
● Power plant-water treatment;
● Water plants and sewage plants-wastewater treatment;
● Papermaking-production process/wastewater treatment;
● Chemical oil refining-production process/wastewater treatment;
● Metallurgy and mining-production process/wastewater treatment;
● Food and beverage-production process/wastewater treatment;
● Semiconductor-production process/wastewater treatment/high-purity
water production.
Technical Parameters
| Product Name | TDS Conductivity meter | 
| Product Model | AEC2-H3A | 
| Software Version | DRFN conductivity Analysis software V1.0 | 
| Conductivity Measuring Range | 0.00~200.00 mS/cm, full range automatic switching (The measurement range is related to the connected electrode constant) | 
| Temperature Measuring Range | -10~150℃ /14~302℉ | 
| Resistivity Display Range | 0.01Ω.cm~18MΩ.cm | 
| TDS Display Range | 0.000mg/L~500g/L | 
| Salinity Display Range | (0.00~10.0)% | 
| Conductivity Resolution | 0.001μS/cm | 
| Resistivity Resolution | 0.01Ω.cm | 
| TDS Resolution | 0.001mg/L | 
| Salinity Resolution | 0.01% | 
| Temperature Resolution | 0.1℃/ 0.1℉ | 
| Accuracy | 0.1% of measuring range | 
| Stability | 0.05% of the measuring range every 24 hours, no accumulation | 
| Repeatability | Better than 0.1% of the measuring range | 
| Sensor diagnosis | Screen image display | 
| Relay Control | 2 settable SPST relays max. load 3A/250VAC | 
| Analog Current Output | 2 settable 0/4~20mA active current loop output max. load 1000Ω | 
| Communication Method | Two-wire RS485 interface, MODBUS RTU | 
| Display Screen | 128*64 LCD, adjustable backlight mode | 
| Configuration information | Power failure protection, indefinite retention of parameters | 
| Time history/data | Year/month/day/hour/minute/second, 14000 historical data can be recorded, and the recording interval can be set between 1 and 999 minutes | 
| Maintain Records | Last 100 times | 
| Protection Level | IP66 | 
| Operating Environment | 0~60℃, relative humidity less than 95% | 
| Storage Environment | -20~70℃, relative humidity less than 55% | 
| Shell Material | Enhanced ABS | 
| Dimensions | 144*144*120mm (hole size 138*138 mm) | 
| Mounting Method | Wall, pipe clamping, panel | 
| Electrical interface | Three M12*1.5 Gellen heads are reserved at the back of the instrument, with a wire diameter of 3~6.5mm. | 
| Power Supply | 100~240V AC | 
| Weight | 800g | 
| Power Consumption | 5W | 
Recommended Conductivity Sensors
| Model | Measuring method | K-value | Measuring range | Temperature compensation | 
| ASC100 | Graphite 2-pole electrode | 1 | 0~20000μS/cm | No | 
| ASC200 | Graphite 2-pole electrode | 1 | 0~20000μS/cm | PT or NTC | 
| ASC400 | Planar 4-pole electrode | 0.5 | 0~200000μS/cm | No | 
| ASCK1 | 2-pole conductivity cell electrode | 1 | 1~2000μS/cm | PT or NTC | 
| ASCK01 | 2-pole conductivity cell electrode | 0.1 | 0.1~200μS/cm | PT or NTC | 
| ASCK001 | 2-pole conductivity cell electrode | 0.01 | 0.01~20μS/cm | PT or NTC | 
|   | 
 Salinity 4 Electrodes Online Conductivity Analyzer For Wastewater Treatment
                                                                                    
                        
                        
                        
                                                            Salinity 4 Electrodes Online Conductivity Analyzer For Wastewater Treatment
                                                    
                        
                     Graphite 2 Electrode Conductivity Analyzer For Drinking Water Treatment
                                                                                    
                        
                        
                        
                                                            Graphite 2 Electrode Conductivity Analyzer For Drinking Water Treatment
                                                    
                        
                     Digital Modbus RS485 Inductive Conductivity Sensor With Temperature Compensation
                                                                                    
                        
                        
                        
                                                            Digital Modbus RS485 Inductive Conductivity Sensor With Temperature Compensation
                                                    
                        
                     Graphite 2 Electrode Conductivity Analyzer With Temperature Compensation
                                                                                    
                        
                        
                        
                                                            Graphite 2 Electrode Conductivity Analyzer With Temperature Compensation
                                                    
                        
                     Online TDS Conductivity Probe 2 Electrode Stainless Steel IP68 For Drinking Water
                                                                                    
                        
                        
                        
                                                            Online TDS Conductivity Probe 2 Electrode Stainless Steel IP68 For Drinking Water
                                                    
                        
                     0.01μS / Cm Conductivity Analyzer With Temperature Compensation IP68
                                                                                    
                        
                        
                        
                                                            0.01μS / Cm Conductivity Analyzer With Temperature Compensation IP68
                                                    
                        
                     Ultra Pure Water Measurement Conductivity Sensor 2 Electrode Conductivity Cell
                                                                                    
                        
                        
                        
                                                            Ultra Pure Water Measurement Conductivity Sensor 2 Electrode Conductivity Cell
                                                    
                        
                     IP66 Conductivity Analyzers 2 Current Outputs For Water Treatment Plant
                                                                                    
                        
                        
                        
                                                            IP66 Conductivity Analyzers 2 Current Outputs For Water Treatment Plant
                                                    
                        
                     Graphite 2 Electrodes Digital Conductivity Probes Water Quality Analysis
                                                                                    
                        
                        
                        
                                                            Graphite 2 Electrodes Digital Conductivity Probes Water Quality Analysis
                                                    
                        
                     Graphite 2 Electrodes Digital Conductivity Analyzer Corrosion Resistant
                                                                                    
                        
                        
                        
                                                            Graphite 2 Electrodes Digital Conductivity Analyzer Corrosion Resistant