| Sign In | Join Free | My carsrow.com | 
 | 
| Categories | Water Quality Sensor | 
|---|---|
| Brand Name: | kacise | 
| Model Number: | KAN601 | 
| Certification: | CE,FDA | 
| Place of Origin: | CHINA | 
| MOQ: | 0-100 | 
| Price: | $0-$2000 | 
| Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram | 
| Supply Ability: | 100 | 
| Delivery Time: | 10-15 days | 
| Packaging Details: | Common package or custom package | 
| Measuring range: | 0~10.00mg/L(0~100.00mg/L) | 
| Resolution: | 0.1mg/L | 
| Accuracy: | ±10% or ±1mg/L | 
| Working pressure: | <0.1MPa | 
| Temperature compensation: | Temperature compensation (Pt1000) | 
| Output: | Digital Sensor,Support RS-485,MODBUS protocol | 
| Power supply: | 12-24VDC (10-30VDC) | 
| Output signal: | 4~20mA,RS485 optional | 
| Company Info. | 
| Xi'an Kacise Optronics Co.,Ltd. | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
Ip68 4~20mA RS485 Ammonia Nitrogen Sensor For Water Quality
Kacise KAN601 Online Ammonia Nitrogen Sensor Patented Probe IP68
Protection Level Easy To Install: 3/4 NPT Thread
KAN601 Online Ammonia Nitrogen Sensor
KAN601 integrated online ammonia nitrogen sensor is fabricated using a PVC membrane-based ammonium ion selective electrode for testing ammonium ion content in water with temperature compensation to ensure fast, simple, accurate and economical testing. The technical parameters, maintenance and communication protocols of the ammonia nitrogen sensor are described in detail in this user manual.
| Model | KAN601 | 
| Measuring range | 0~10.00mg/L(0~100.00mg/L) | 
| Resolution | 0.1mg/L | 
| Accuracy | ±10% or ±1mg/L | 
| Working temperature | 0~40℃ | 
| Working pressure | <0.1MPa | 
| Medium PH range | 4~10 pH | 
| Temperature compensation | Temperature compensation (Pt1000) | 
| Power supply | 12~24 VDC ±10% | 
| Signal output | RS-485 bus, Modbus/RTU protocol | 
| Wetted material | PVC and POM | 
| Installation | 3/4NPT thread, immersion installation | 
| Cable length | 5 meters, other lengths can be customized | 
| Calibration | Two-point calibration | 
| Power consumption | <0.3W@12V | 
| Protection grade | IP68 | 
Dimensional Drawing
The measurement principle of titration method:
This method is only suitable for water samples that have been pretreated by distillation. Adjust the pH value of the water samples within the range of 6.0-7.4, and add magnesium oxide to make them slightly alkaline. The ammonia released by heating and distillation is absorbed by the boric acid solution. Using methyl blue-methylene blue as an indicator, the ammonium in the solution is distilled out by titration with a standard solution. When the solution contains materials that may be distilled out under these conditions and react with acid during titration, the measured data will be higher.
Website www.kacise.com
Phone +86-17719566736
Email sales@kacise.com
Location Tangyan South Road, High-tech Zone, Xi'an City, Shaanxi
Province, China
|   | 
 Intelligent Water Quality Sensor Fiber Optic Chlorophyll Sensor RS485 Transmission
                                                                                    
                        
                        
                        
                                                            Intelligent Water Quality Sensor Fiber Optic Chlorophyll Sensor RS485 Transmission
                                                    
                        
                     Aquaculture Fluorescence Dissolved Oxygen Sensor High Accuracy 22mm Casing Diameter
                                                                                    
                        
                        
                        
                                                            Aquaculture Fluorescence Dissolved Oxygen Sensor High Accuracy 22mm Casing Diameter
                                                    
                        
                     Accurate 10% 	Water Quality Sensor RS485 Output Multi Parameter
                                                                                    
                        
                        
                        
                                                            Accurate 10% 	Water Quality Sensor RS485 Output Multi Parameter
                                                    
                        
                     Environmentally Friendly COD Sensor / Kws-100 Cod Measurement Instrument
                                                                                    
                        
                        
                        
                                                            Environmentally Friendly COD Sensor / Kws-100 Cod Measurement Instrument
                                                    
                        
                     NH4-N Ammonia Nitrogen Water Quality Sensor KWS-200 PH Range 4-10
                                                                                    
                        
                        
                        
                                                            NH4-N Ammonia Nitrogen Water Quality Sensor KWS-200 PH Range 4-10
                                                    
                        
                     90° Scattered Light Aquaculture Industry Water Turbidity Sensor 0 - 1000NTU Measuring Range
                                                                                    
                        
                        
                        
                                                            90° Scattered Light Aquaculture Industry Water Turbidity Sensor 0 - 1000NTU Measuring Range
                                                    
                        
                     Radial Installation Manometer Pressure Gauge Pressure Monitoring Storage
                                                                                    
                        
                        
                        
                                                            Radial Installation Manometer Pressure Gauge Pressure Monitoring Storage
                                                    
                        
                     Electromagnetic flowmeter for measuring liquid flow 0.6-4.0MPa pressure with accuracy 0.5%
                                                                                    
                        
                        
                        
                                                            Electromagnetic flowmeter for measuring liquid flow 0.6-4.0MPa pressure with accuracy 0.5%
                                                    
                        