| Sign In | Join Free | My carsrow.com |
|
| Categories | Ceramic Resonator |
|---|---|
| Brand Name: | HM |
| Model Number: | ceramic resonator 10.00Mhz ZTTCE10.00MG50HD0-R0 |
| Certification: | Rohs,ISO |
| Place of Origin: | wuxi |
| MOQ: | 1000 |
| Price: | $0.5 |
| Payment Terms: | paypal, Western Union, MoneyGram |
| Supply Ability: | 1000000pcs PER YEAR |
| Delivery Time: | 35 day |
| Packaging Details: | REEL |
| Oscillation Frequency Fosc (MHz): | 10.00Mhz |
| Frequency Accuracy (%): | ±0.5 max |
| Resonant Impedance Ro (Ω): | 40 max |
| Temperature Coefficient of Oscillation Frequency (%) max.: | ±0.3 (Oscillation Frequency drift,-25℃~+85℃) |
| Oscillation Frequency Aging Rate(10years) (%) max: | ±0.2 (From initial value) |
| Withstanding Voltage (V): | 50 (DC,1min) |
| Insulation Resistance Ri,(MΩ)min.: | 500 (10V,1min) |
| Temperature Stability (-20℃~ +80℃ ): | ±0.5% max (-25℃ ~ +80℃) |
| Rating Voltage UR(V): | 15V p-p |
| Operating Temperature: | -25℃ ~ +85℃ |
| Storage Temperature: | -55℃ ~ +85℃ |
| Insulation Resistance(DC 25V 1 minute): | 100MΩ min |
| Input/Output Impedance: | 330 Ω |
| Company Info. |
| hanse-john electronic Co.,Ltd. |
| View Contact Details |
| Product List |

| NO. | Components | Materials |
| 1 | Outer Electrodes | Top and Bottom ElectrodesAg+Ni(under plating)+Sn(over plating) Side ElectrodesNi+Cu+Ag(under plating)+Sn(over plating) |
| 2 | Ceramic Box | Insulation Box |
| 3 | Cover | Dielectric Material |
| 4 | Glue | Epoxy Resin |
| 5 | Conductive Adhesive | Ag+Epoxy Resin |
| 6 | Base | Dielectric Material |
| 7 | Ceramic Element | Piezoelectric Ceramics (PZT) |
4.ELECTRICAL SPECIFICATIONS
4.1 RATING
| Items | Requirement |
| Withstanding Voltage (V) | 50 (DC,1min) |
| Insulation Resistance Ri,(MΩ)min. | 500 (10V,1min) |
| Operating temperature | -25℃~+85℃ |
| Storage temperature | -55℃~+85℃ |
| Rating Voltage UR(V) | 6V DC |
| 15V p-p |
4.2 ELECTRICAL SPECIFICATIONS
| Items | Requirement |
| Oscillation Frequency Fosc (MHz) | 10.000 |
| Frequency Accuracy (%) | ±0.5 |
| Resonant Impedance Ro (Ω)max. | 40 |
Temperature Coefficient of OscillationFrequency (%) max. | ±0.3 (Oscillation Frequency drift,-25℃~+85℃) |
Oscillation Frequency Aging Rate(10years) (%) max | ±0.2 (From initial value) |
*Components shall be left in a chamber of +85±2℃ for 1000 hours, then measured after leaving in natural condition for 1 hour.
5.TEST
5.1 Test Conditions
Parts shall be tested under the condition ( Temp.:20±15℃,Humidity :65±20%
R.H.) unless the standard condition(Temp.:25±3℃,Humidity :65±10% R.H.)
is regulated to measure.
| No | Item | Condition of Test | Performance Requirements | |
| 6.1 | Humidity | Keep the resonator at 40℃±2℃ and 90%-95% RH for 96h. Then Release the resonator into the room Condition for 1h prior to the Measurement. | It shall fulfill the specifications in Table 1. | |
| 6.2 | High Temperature Exposure | Subject the resonator to 85±2℃ for 96h, then release the resonator into the room conditions for 1h prior to the measurement. | It shall fulfill the specifications in Table 1. | |
| 6.3 | Low Temperature Exposure | Subject the resonator to -55±2℃ for 96h, then release the resonator into the room conditions for 1h prior to the measurement. | It shall fulfill the specifications in Table 1. | |
| 6.4 | Temperature Cycling | After temperature cycling of blow table was performed 5 times, resonator shall be measured after being placed in natural conditions for 1h. | It shall fulfill the specifications in Table 1. | |
| Temperature | Time | |||
| –25±3℃ | 30±3 min | |||
| 85±3℃ | 30±3 min | |||
| 6.5 | Vibration | Subject the resonator to vibration for 2h each in x,y and z axis With the amplitude of 1.5mm, the frequency shall be varied uniformly between the limits of 10 Hz—55Hz. | It shall fulfill the specifications in Table 1. | |
| 6.6 | Mechanical Shock | Drop the resonator randomly onto a wooden floor from the height of 100cm 3 times. | It shall fulfill the specifications in Table 1. | |
6.7 | Soldering Test | Passed through the re-flow oven under the following condition and left at room temperature for 1h before measurement. | It shall fulfill the specifications in Table 1. | |
![]() | ||||
Table 1





|