| Sign In | Join Free | My carsrow.com | 
 | 
| Categories | Light Testing Equipment | 
|---|---|
| Brand Name: | kingpo | 
| Certification: | iso9001 ce | 
| Place of Origin: | china | 
| MOQ: | 1 | 
| Price: | To be quoted | 
| Payment Terms: | T/T | 
| Packaging Details: | safety carton pack or plywood box | 
| Standard: | IEC 61347-1:2012, clause 14.6 | 
| working voltage: | <1000Vac | 
| working frequency: | 50/60Hz | 
| working current: | <500Aac<500Aac | 
| flow: | 160A +10% -0% current constantly | 
| Function: | current test device | 
| Delivery Time: | 7 working days | 
| Supply Ability: | 50 pcs per month | 
| Company Info. | 
| KingPo Technology Development Limited | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
IEC 61347-1-2012-Figure 3 Test Circuit for Controlgear
Test principle
This tester is a current test device developed according to the IEC 61347-1:2012 standard, Article 14.6 requires current compliance; through the tester current measurement, it can determine whether the test conditions meet the "standard".
Test Methods
1.1. According to the IEC 61347-1:2012 standard, clause 14.6 a requires that the circuit be connected, as shown in figure (1) :

1.2 Adjust the oscilloscope input display ratio to X1, Y-axis adjustment to 1V/div, X-axis adjustment to 20mS/div, and the synchronization status is set to normal synchronization.
1.3 For example: connect the power supply, the oscilloscope waveform is the current of the test device, and the waveform is shown in figure 2.

Current reading method: peak voltage: 1.9V, peak current 190A (current to voltage ratio 100:1) RMS voltage: 1.34V, RMS current is 134A
According to the requirements of IEC 61347-1:2012, power supply and test equipment can be qualified to flow 160A +10% -0% current constantly.
2.1 According to IEC 61347-1:2012 standard, Clause 14.6-b connects the tested products, as shown in Figure below

3.1 According to IEC 61347-1:2012 standard, Clause 14.6-C, connect to the power supply for testing, oscilloscope setting method and current reading method is the same as 1.2,1.3.
Technical Parameters
1, working voltage: <1000Vac
2, working frequency: 50/60Hz
3, working current: <500Aac<500Aac
Note:




|   | 
 Circuit Light Testing Equipment Rectifying Effect Of High Pressure Sodium And Metal Halide Lamps
                                                                                    
                        
                        
                        
                                                            Circuit Light Testing Equipment Rectifying Effect Of High Pressure Sodium And Metal Halide Lamps
                                                    
                        
                     7006-47C For G5 Lampholders , 7006-60C For G13 Lampholders
                                                                                    
                        
                        
                        
                                                            7006-47C For G5 Lampholders , 7006-60C For G13 Lampholders
                                                    
                        
                     Light Testing Equipment LED Aging Test Device 1000 Hours Test Duration
                                                                                    
                        
                        
                        
                                                            Light Testing Equipment LED Aging Test Device 1000 Hours Test Duration
                                                    
                        
                     IEC 60598-1 Clause 8.15 Arrangement For Impact Test For Handlamps With A Handle Or Shell Of Flexible Material
                                                                                    
                        
                        
                        
                                                            IEC 60598-1 Clause 8.15 Arrangement For Impact Test For Handlamps With A Handle Or Shell Of Flexible Material
                                                    
                        
                     IEC 61347-1 Annex D Test Chamber Heating Enclosure For Thermally Protected Ballasts / Rectifier Thermal Protection
                                                                                        
                                                        
                        
                        
                        
                                                            IEC 61347-1 Annex D Test Chamber Heating Enclosure For Thermally Protected Ballasts / Rectifier Thermal Protection
                                                    
                        
                     Double-walled cylinder , IEC 60598-1 Annex K Temperature measurement
                                                                                    
                        
                        
                        
                                                            Double-walled cylinder , IEC 60598-1 Annex K Temperature measurement
                                                    
                        
                     Measurement Lab Test Machines Of Touch Current And Protective Conductor Current
                                                                                    
                        
                        
                        
                                                            Measurement Lab Test Machines Of Touch Current And Protective Conductor Current
                                                    
                        
                     IEC61347-1-Figure G.2 Circuit For Producing And Applying Long - Duration Pulses
                                                                                    
                        
                        
                        
                                                            IEC61347-1-Figure G.2 Circuit For Producing And Applying Long - Duration Pulses
                                                    
                        
                     IEC 62262 IK Pendulum Hammer , Pendulum Impact Hammer For Specifying Enclosure Capacity
                                                                                    
                        
                        
                        
                                                            IEC 62262 IK Pendulum Hammer , Pendulum Impact Hammer For Specifying Enclosure Capacity
                                                    
                        
                     Electrodynamic Vibration Test Systems Large Displacement Vertical Or Horizontal Operation
                                                                                    
                        
                        
                        
                                                            Electrodynamic Vibration Test Systems Large Displacement Vertical Or Horizontal Operation