| GI Series Low Frequency Pure Sine Wave Inverter (220V) |
| Model | GI-102 | GI-152 | GI-202 | GI-302 | GI-402 | GI-502 | GI-602 |
| Rated Power | 1KW | 1.5KW | 2KW | 3KW | 4KW | 5KW | 6KW |
| Peak Power | 3KW | 4.5KW | 6KW | 9KW | 12KW | 15KW | 18KW |
| Nominal battery voltage | 12/24VDC | 12/24/48VDC | 24VDC/48VDC |
| Input | DC input range | 10.5-15VDC (12V) / 21-30VDC (24V) / 42-60VDC (48V) |
| AC Mains input range | 170-275VAC (220/230/240VAC)±4% |
| AC input frequency | 50Hz: 45-65Hz / 60Hz: 55-65Hz±0.5Hz (50Hz/60Hz automatic
recognition) |
| Protection | Low battery alarm | ≤10.5VDC (12V) / ≤21VDC (24V) / ≤42VDC (48V) alarm |
| Low battery protection | ≤10VDC (12V) / ≤20VDC (24V) / ≤40VDC (48V) automatic shutdown |
| High battery alarm | ≥15VDC (12V) / ≥30VDC (24V) / ≥60VDC (48V) alarm |
| High battery protection | ≥17VDC (12V) / ≥34VDC (24V) / ≥68VDC (48V) automatic shutdown |
| Over load protection | 110%<loading<150%, shutdown after 60s alarm, loading>150%,
shutdown after 20s alarm |
| High temperature | Built-in temperature real time sensor, ≥85℃ alarm, ≥90℃ automatic
shutdown |
| Short circuit protection | Automatic shutdown |
| Output | Transfer efficiency | ≥92% |
| Output voltage | (DC battery mode) 220/230/240VAC±2% |
| Output frequency | (DC battery mode) 60/50Hz±1% |
| Output wave form | Pure sine wave |
| Output voltage | (AC mains mode) stable 220/230/240VAC±10% output (built-in AVR
stablizer) |
| AVR output stablizer | AC mains<170VAC±5% swtich to DC battery mode, AC mains>180VAC
±5% return to AC mains mode; |
| AC mains>275VAC±5% swtich to DC battery mode, AC mains<255VAC
±5% return to AC mains mode; |
| The above is for output 220V system reference, 230V/240V output
just multiply by percentage |
| Output frequency | (AC mains mode) automatic tracing from AC input |
| Other | Transfer time | ≤4ms |
| Display | LCD Display with function buttons |
| Cooling system | Intelligent cooling fan control system |
| ≤42℃ slow fan, ≥45℃ fast fan |
| AC Charger | 7 battery types mode | Gel U.S.A. / Gel European / A.G.M.1 / A.G.M.2 / Sealed lead acid /
Open lead acid / Calcium(open) / |
| Deep sulphation cycle 15.5 for 4 hrs |
| AC charging Voltage | 13.6-14.2VDC(12V)/27.2-28.4VDC(24V)/54.4-56.8VDC(48V) |
| AC charging current | 0-35A: 5A / 10A / 20A / 25A / 30A / 35A, 6 stages adjustable option |
| 3 Stages charging | Boost charging, direct charging, float charging |
| AC over charge protection | Battery voltage ≧16VDC (12V) ≧32VDC (24V) ≧64VDC (48V), stop
charging after 60s alarm |
Working mode (Optional) | 01 | AC mains priority |
| Always use AC mains as priority input to provide AC output and
automatically charge the battery, only |
| stops charging when battery is fully charged, and only starts DC to
AC converting untill AC mains is off |
| 02 | Energy saving |
| Loading≤10% automatic shutdown, loading≥11%-100% automatic turn on |
| 03 | DC battery priority |
| Always use DC battery as priority input to provide AC output, for
12V system, when battery≥13V, starts |
| DC to AC converting; when battery≤10.5V during converting, switch
to AC mains mode to provide AC |
| output and automatically start charging the battery (for 24V/48V
system, multiply by 2/4 accordingly) |
| Comnunication | RS-232/USB/SNMP(additional option) |
| Environment | Temperature | -20~75℃ |
| Humidity | <95% |
| Appearance | Product size (mm) | 430*310*270mm | 600*270*200mm |
| Packing size (mm) | 540*350*300mm | 720*310*270mm |
| Net Weight (kg) | 15kg | 17kg | 24.5kg | 29kg | 44kg | 48.1kg | 49.5kg |
| Gross Weight (kg) | 16.5kg | 19kg | 27kg | 31kg | 46kg | 50.1kg | 52.2kg |
| *Product specifications are subject to change without further