PID SSR Control UV Aging Test Chamber / Ultraviolet UVA Light Tester In Lab

Categories Aging Test Chamber
Place of Origin: Guangdong, China (Mainland)
Brand Name: HAIDA
Certification: ISO 9001:2000; ISO 9001:2008; QS-9000; ISO 14001:2004; CE, , SMC, CMC, CPA, CE,CMA,IMC
Model Number: HD-802
MOQ: 1 Set
Price: Negotiable
Packaging Details: Each set protected with resin fiber and PP film, then put into Strong wooden case with operation man
Delivery Time: 20 days after order confirmed
Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram,In cash, escrow
Supply Ability: 300 Sets per Month Haida
Controller: Korean TEMI 880 programmable controller
Humidity range: about 45%~70% R.H.
Material: SUS 304 steel
USE: UV Aging Test Chamber
product name: uv test chamber
Temperature control: PID SSR control
Voltage: 220V/50Hz /±10% 5KW
Studio Size: 1140Wmm×400Dmm×500Hmm
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

PID SSR Control UV Aging Test Chamber / Ultraviolet UVA Light Tester In Lab

PID SSR Control UV Aging Test Chamber / Ultraviolet UVA Light Tester In Lab


Product Description:

The world's most widely used UV aging chamber, which is used in more labs throughout the world than any other accelerated weathering tester.

Standard has become the world standard in the accelerated weathering test in lab.

The damage of the material caused by the sunshine rain and dew reappears quickly and truly. It only needs several days or weeks to reappear the damage by using QUV, which damage appears in the several months or years under outdoor condition. These damages include: bleaching, discoloration, loss of light, powder, crack, turbidity, bubble-based, embrittlement, strength decline and oxidation.

According to the reliable aging test date, you can predict the ageing resistance of the products, and is helpful to choose optimize the products.

It's used widely in the industry, such as coating, printing ink, paint, resin, plastics, print, packaging, bond, motor van, makeup, metal, electron, galvanization, medical, and so on



Technical parameters:

ItemSpecification
Outside dimension1140Wmm×400Dmm×500Hmm
Chamber materialSUS#304 stainless steel
Temperature rangeRT~70℃
Temperature fluctuation±2℃
Temperature controlPID SSR control-PID self - tuning temperature control mode
Humidity range:about 45%~70% R.H.
ControllerProgrammable controller, LCD touch screen
Control modeBalance temperature humidity control (BTHC)
Test cycle settingExposure, condensation and water spray test cycle is programmable
Lamp power40W/Piece
Distance from sample to lamp50±2mm
Centre distance between the lamp70mm
Irradiance0.45~0.8W/m2 (optional)
UV lampsImported Atlas UV-A: 315-400nm (8pcs, 1600h lifetime)
Standard Specimen Size75×150mm (48pcs)
Testing time0~999H, adjustable
Protection system

Overload short circuit protection

Over temperature protection

Water lacking protection

Earth leakage protection

Auto shut off protection


Chamber Structure:

The inner bladder of the chamber is made of imported high-class stainless steel plate while the outer bladder is made of SUS 304 steel plate.

The heating mode adopts inner bladder trough type heating with its rapid temperature rise and even temperature distribution.


Control System:
Adopts black aluminum plate to connect temperature sensor and adopts black board temperature meter to control heating so as to ensure more stable temperature.
The radiometer probe is fixed so as to avoid the frequent installation and disassembly.
The radiation quantity adopts the special UV irradiatometer with high-precision display and measurement.
The radiation intensity is not more than 50W/m2.
The illumination and condensation can be controlled independently or alternating and circularly.


Test Specimen Mounting:

The standard test specimen holder accommodates 2 panels 75×150mm. The test panels are actual the side wall of the chamber. To properly seal the chamber, it is important to have every panel holder filled with specimens or blank panels and to have panel holders in place.


Design Criteria:
(1) ASTM D4587: Standard Practice for Fluorescent UV-Condensation Exposures of Paint and Related Coatings
(2) ASTM D4799: Standard Practice for Accelerated Weathering Test Conditions and Procedures for Bituminous Materials (Fluorescent UV, Water Spray, and Condensation Method)
(3) ISO 4892-1: Plastics – Methods of Exposure to Laboratory Light Sources – Part 1: General guidance
(4) ISO 4892-3: Plastics - Methods of Exposure to Laboratory Light Sources - Part 3: Fluorescent UV Lamps
(5) ASTM D4329: Standard Practice for Fluorescent UV Exposure of Plastics
(6) AATCC TM186: Weather Resistance: UV Light and Moisture Exposure
(7) ASTM D5208: Standard Practice for Fluorescent Ultraviolet (UV) Exposure of Photodegradable Plastics
(8) IEC 61345: UV Test for Photovaltalic (PV) Modules


Poduct Image:


Quality PID SSR Control UV Aging Test Chamber / Ultraviolet UVA Light Tester In Lab for sale
Send your message to this supplier
 
*From:
*To: Dongguan Haida Equipment Co.,LTD
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0